OBSERVED  
PROBLEM 
 
ODS/PILOT lights but flame 
goes out when control knob is 
released 
 
4.  Air in gas lines when 
installed 
 
5.  Depleted gas supply 
 
6.  ODS/Pilot is clogged 
 
7.  Gas regulator setting is not 
correct 
 
POSSIBLE  
PROBLEM 
 
1.  Control knob is not fully 
pressed in 
2.  Control knob not pressed in 
long enough 
 
3.  Safety interlock system has 
been triggered (if equipped) 
4.  Manual shutoff valve not 
fully open 
5.  Thermo-couple connection 
loose at control valve. 
6.  Pilot flame not touching 
thermo-couple, which 
allows thermo-couple to 
cool, causing pilot flame to 
go out.  This problem can be 
caused by one or both of the 
following: 
 
 
A) Low gas pressure 
  B) 
Dirty 
or 
partially 
 
 
     clogged  ODS/Pilot 
7.  Control valve damaged 
 
4.  Continue to hold down control 
knob.  Repeat igniting 
operation until air is removed. 
5.  Contact local propane gas 
company 
6.   Clean ODS/Pilot or replace 
ODS/Pilot assembly 
7.    Replace gas regulator 
 
 
 
SOLUTION 
 
1.  Press control knob completely 
 
2.  After ODS/Pilot lights keep 
control knob pressed  30 
seconds 
3.  Wait 1 minute for safety 
interlock system to reset. 
4.  Fully open manual shutoff 
valve. 
5.  Hand tighten until snug, then 
tighten 1/4 turn 
6.  A) Contact local propane gas 
company 
 
B) Clean ODS/Pilot (See 
Cleaning and Maintenance), 
or replace ODS/Pilot 
assembly 
 
 
 
 
7.  Replace valve control 
Page 34