WARNING 
 
IF YOU SMELL GAS: 
 
 
*  SHUT OFF GAS SUPPLY 
 
 
*  DO NOT TRY TO LIGHT APPLIANCE 
 
 
*  DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY  
 
 
    PHONE  IN YOUR BUILDING 
 
 
*  IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S 
 
 
    PHONE.  FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS. 
 
 
*  IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE  
 
 
    DEPARTMENT. 
 
IMPORTANT:
  Operating heater where impurities in the air exist may create odors.  Cleaning 
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc. create 
fumes.  These fumes may mix with combustion air and create odor. 
 
OBSERVED 
PROBLEM 
 
H e a t e r   p r o d u c e s   a 
clinking/ticking noise just 
after burner is lit or shut 
off 
 
 
Heater produces unwanted 
odors 
 
 
 
 
 
Heater shuts off in use 
(ODS operates) 
 
 
 
 
Gas odor even when 
control knob is in “OFF” 
position 
 
Gas odor during com-
bustion 
 
 
POSSIBLE 
CAUSE 
 
1.  Metal expands while heating 
or contracts while cooling. 
 
 
 
1.  Heater burning vapors from 
paint, hairspray, glues, etc.   
(See Important above) 
2.  Low fuel supply 
3.  Gas leak (See WARNING 
above) 
 
 
1.  Not enough fresh air is 
available 
2.  Low line pressure 
3.  ODS/Pilot is partially clogged 
 
 
1.  Gas leak (See WARNING
above). 
2.  Control valve defect 
 
1.  Foreign matter between 
control valve and burner 
2.  Gas leak (See WARNING 
above) 
 
 
SOLUTION 
 
1.  This is common with most 
heaters.  If noise is excessive, 
contact a qualified service 
person. 
 
1.  Ventilate room.  Stop using odor 
causing products while heater is 
running. 
2.  Refill supply tank 
3.  Locate and control all leaks.  See 
Checking Gas Connections. 
 
 
1 . Open window/door for 
ventilation 
2.  Contact local propane company 
3.  Clean ODS/Pilot 
 
 
1.  Locate and correct all leaks (see 
Checking Gas Connections) 
2.  Replace control valve 
 
1.  Remove foreign matter from gas 
tubing 
2.  Locate and correct all leaks (see 
Checking Gas Connections) 
Page 35