Monessen Hearth CSVF30SNV Benutzerhandbuch

Seite von 32
20 
58D6002
PIL
OT
OFF
REMO
TE C
ONTROL 
Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.
 
In addition, periodically check the flames visually during operation.
CHECKING PILOT FLAME
The pilot flame must always be present when the heater is in operation. 
It should just touch the top of the ther-
mocouple tip for natural. See Figure 19 for correct pilot flame. 
If the pilot flame does not touch the thermocouple, then the burners cannot function reliably. See Figure 20 for incorrect 
shape of pilot flame.
MILLI-VOLT CONTROL
Figure 19 - Correct Appearance of Pilot Flame
Figure 20 - Incorrect Appearance of Pilot Flame
Thermocouple
for Natural  
Thermocouple
for LP
Thermocouple
for LP
Thermocouple
for Natural 
ROCK WOOL INSTALLATION  
Figure 18 - Rock Wool Installation 
1.   Break rock wool into dime-sized pieces. 
 
2.   Place rock evenly across rock wool tray and front burner as shown in 
Figure 18.
    •  Rock wool depth must not be more than 1".
    •  Do not place rock wool past the bend in rock wool tray.
    •  Do not place rock wool on rear burner. 
FLAME APPEARANCE 
Rock Wood 
Tray 
Rock Wool 
Bend in Rock 
Wool Tray 
Rock  wool  must  be  placed 
correctly.  Placing  rock  wool 
in  wrong  area  will  create  high 
carbon monoxide.  
W
ARNING