INTRODUCTION
Introduction
Always consult your local Building Department regarding regu-
lations, codes or ordinances which apply to the installation of a 
vented room heater.
Instructions to Installer
1. Installer must leave instruction manual with owner after instal-
lation.
2. Installer must have owner fill out and mail warranty card sup-
plied with heater.
3. Installer should show owner how to start and operate heater 
and thermostat.
General Information
This series is design certified in accordance with American National 
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Stan-
dards Association, as a Vented Room Heater and must be installed 
according to these instructions.
Any alteration of the original design, installed other than as 
shown in these instructions or use with a type of gas not shown 
on the rating plate is the responsibility of the person and com-
pany making the change.
Important
All correspondence should refer to complete Model Number, Serial 
Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out and 
smoke will occur. To prevent triggering of smoke alarms, ventilate 
the room in which the unit is installed.
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or other 
combustible material, other than wood flooring, the appliance shall 
be installed on a metal or wood panel extending the full width and 
depth of the appliance.
The base referred to above does not mean the fire-proof base as 
used on wood stoves. The protection is primarily for rugs that may 
be extremely thick and light-color tile that can discolor.
Floor pad is available from Empire Comfort Systems, Inc., Part 
Number RH-425.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall be 
performed only by a qualified agency. The term “qualified agency” 
means any individual, firm, corporation, or company which whether 
in person or through a representative is engaged in and is respon-
sible for (1) the installation or replacement of gas piping or (b) the 
connection, installation, repair or servicing of equipment, who is 
experienced in such work, familiar with all precautions required 
and has complied with all the requirements of the authority having 
jurisdiction.
The installation must conform with local codes, or in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1*/
Canadian Installation Code, CAN/CGA B149.
*Available from the American National Standards Institute, Inc., 11 West 42nd St., 
New York, N.Y. 10036
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings should 
be reduced at the rate of 4 percent for each 1,000 feet (305m) above 
sea level. Canadian High Altitudes for locations having an eleva-
tion above mean sea level between 2,000 feet (610m) and 4,500 feet 
(1370m), the manifold pressure is to be decreased from 4.0” w.c. 
(.996kPa) to 3.2” w.c. (.797kPa) for Natural Gas and from 10.0” 
w.c. (2.49kPa) to 8.0” w.c. (1.99kPa) for Propane Gas.
State  of  Massachusetts:  The  installation  must  by  made  by 
a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of  
Massachusetts
SPECIFICATIONS
Models
RH-50B
RH-65B
RH-50C
RH-65C
RH-50CB
RH-65CB
Input BTU/HR (KW/H)
50,000 (14.6)
65,000 (19)
50,000 (14.6)
65,000 (19)
50,000 (14.6)
65,000 (19)
Height
29 9/16” (751mm)
29 9/16” (751mm)
29 9/16” (751mm)
29 9/16” (751mm)
29 9/16” (751mm)
29 9/16” (751mm)
Width
34” (864mm)
34” (864mm)
34” (864mm)
34” (864mm)
34” (864mm)
34” (864mm)
Depth including diverter
23 3/16” (589mm)
27 11/16” (704mm)
23 3/16” (589mm)
27 11/16” (704mm)
23 3/16” (589mm)
27 11/16” (704mm)
Gas Inlet
1/2” (13mm)
1/2” (13mm)
1/2” (13mm)
1/2” (13mm
1/2” (13mm)
1/2” (13mm)
Size Draft Diverter Collar
5” (127mm)
5” (127mm)
5” (127mm)
5” (127mm)
5” (127mm)
5” (127mm)
Floor to top of collar on vertical 
position of Draft Diverter
27 5/32” (690mm)
27 5/32” (690mm)
27 5/32” (690mm)
27 5/32” (690mm)
27 5/32” (690mm)
27 5/32” (690mm)
Floor to center of collar on 
horizontal position of Draft Diverter
22 9/16” (573mm)
22 9/16” (573mm)
22 9/16” (573mm)
22 9/16” (573mm)
22 9/16” (573mm)
22 9/16” (573mm)
Accessories
Blower Package
Included
Included
FRB-3
FRB-3
Included
Included
Radiant Package
RAD-8
RAD-8
N/A
N/A
N/A
N/A
Floor Pad
RH-425
RH-425
RH-425
RH-425
RH-425
RH-425
Ceramic Log
RHL-1
RHL-1
N/A
N/A
N/A
N/A