Empire Products RH-50-6 Benutzerhandbuch

Seite von 20
12822-3-0406
Page 8
VENT SAFETY SHUTOFF SYSTEM
This heater must be properly connected to a venting system. This 
heater is equipped with a vent safety shutoff system.
This appliance needs fresh air for safe operation and must be 
installed so there are provisions for adequate combustion and 
ventilation air.
This room heater is equipped with a vent safety switch. The vent 
safety switch will cause gas flow to the pilot to “shut off” due to 
improper venting or a blocked flue.
If the vent safety switch continues to “shut off” the gas flow to 
the pilot, a qualified service person must be contacted to inspect 
for improper venting, blockage in the vent pipe or the vent safety 
switch for being defective.
Warning:
Operation  of  this  heater,  when  not  connected  to  a  
properly  installed  and  maintained  venting  system  or  
tampering with the vent safety shutoff system, can result in 
carbon monoxide (CO) poisoning and possible death.
REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER
This room heater has a reversible draft diverter. The draft diverter 
is installed in the vertical position at the factory. Please use the 
following steps to change the draft diverter from the vertical 
positing to the horizontal position.
1. Remove L280 vent safety switch from the draft diverter.
2. Inside your yellow instruction envelope will be a 1 1/2” x 2 
1/4” (38mm x 51mm) vent safety switch hole cover plate and 
two (2) 1/2” screws for attachment of vent safety switch hole 
cover plate to the draft diverter. Attach vent safety switch hole 
cover plate over hole on the draft diverter from which the L280 
vent safety switch was removed.
3. Remove two (2) screws at bottom of draft diverter and lift 
upward to remove draft diverter from the draft diverter plate. 
Rotate draft diverter into the horizontal position and slide back 
into the draft diverter plate. Attach two (2) screws into bottom 
of the drafter diverter.
4. Remove vent safety switch hole knockout and two (2) knockouts 
for screws on opposite side of draft diverter.
5. Attach L280 vent safety switch to the draft diverter.
6. Repositioning of the draft diverter is completed.
DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT 
OR HORIZONTAL VENT
Figure 4
THERMOSTAT OPERATION
To turn on burner, rotate dial knob toward setting number 7. To 
shut down burner, rotate dial knob toward setting number 1.
The dial numbers 1 to 7 correspond to 50
o
 to 90
o
F (10
o
 to 32
o
C). 
This temperature at the bulb thermostat, not the room tempera-
ture. The owner is advised to determine the particular heat setting 
that is desired for comfort, as heating requirements are different 
for every owner.
Attention: If no heat is desired, turn the gas control knob to the 
PILOT position.