P35i Fireplace Insert
D.  Existing Fireplace Installation:
If using a short run of venting, whether flex or rigid, 
through the damper and into the chimney flue; The 
Damper must be removed or locked in the open posi-
tion and sealed with a plate constructed of steel or 
other non-combustible material. 
Kaowool, mineral wool or other non-combustible insu-
lation is recommended above the plate to reduce the 
possibility of condensation. You will also need to wrap 
the venting section between the insert frame and the 
damper sealing plate. This is to prevent overheating 
of the fireplace cavity, which may cause damage to 
the insert's motors and other electrical components.
The connector pipe should extend through the sealing 
plate and smoke chamber and into, or beyond the first 
flue tile. 
--
--
Tile F
lue Liner
Non-combustible 
Insulation
Sealing Plate
When using single wall flex, this 
section of venting must be 
wrapped with non-combustible 
insulation to prevent excessive 
heat build-up in the cavity.
When venting in this configuration, a rain cap and 
proper flashing must be installed on the top of the 
chimney to prevent flooding and damage.
Be sure to design the venting so that it can be easily 
cleaned. 
Check with your local authority having jurisdiction to 
determine if this venting method is acceptable. Some 
Provincial, State, or Local codes may require a full  
liner run to the top of the chimney. Be sure and check 
your local regulations before planning the installation. 
In this method, the proper flashing and rain cap are 
also required. 
WARNING
Fire Risk.
Inspect Chimney
•  Masonry chimney must be in good condition
•  Meets minimum of NFPA 211 standard
•  Factory-built chimney must meet requirements 
of UL103 HT
IN CANADA: This fireplace insert 
must be installed with a continuous 
chimney liner of a minimum 3" 
diameter extending from the insert to 
the top of the chimney. The chimney 
liner must conform to the Class 3 
requirements of CAN/ULC-S635, 
Standard for Lining Systems for 
Existing Masonry or Factory Built 
Chimneys and Vents, or CAN/ULC-
S640, Standard for Lining Systems 
for New Masonry Chimneys.