Save These Instructions                                                                    3-90-775                                               Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
NOTE: The restriction of not venting more than one appliance 
to the same flue applies to the U.S. specifically.  While it is not 
recommended that you use the same chimney for more than 
one appliance, in Canada certain exceptions may be made. 
Be sure to contact your building code inspection official to 
see if this option is allowed in your area, and to find out the 
specific requirements for such an installation.
Do  not connect this unit to a chimney 
flue servicing another appliance.
B.  Avoiding Smoke and Odors
Negative Pressure, Shut-down, and Power 
Failure:
T
o reduce the probability of back-drafting or burn-
back in the pellet burning appliance during power 
failure  or  shut-down  conditions,  the  stove  must 
be able to draft naturally without exhaust blower op-
eration. Negative pressure in the house will resist this 
natural draft if not accounted for in the pellet appliance 
installation.
Heat rises in the house and leaks out at upper levels. 
This air must be replaced with cold air from outdoors, 
which flows into lower levels of the house. Vents and 
chimneys into basements and lower levels of the house 
can become the conduit for air supply, and reverse under 
these conditions.
Outside Air:
Harman Home Heating and Hearth & Home Tech-
nologies  recommend  attaching  outside  air  in  all 
installations, especially lower level and main floor 
locations.
Per  national  building  codes,  consideration  must  be 
given to combustion air supply to all combustion appli-
ances. Failure to supply adequate combustion air for all 
appliance demands, may lead to back-drafting of those 
and other appliances. 
When the appliance is side-wall vented: The air intake 
is best located on the same exterior wall as the exhaust 
vent outlet and located lower on the wall than the exhaust 
vent outlet.
When the appliance is roof vented: The air intake is 
best located on the exterior wall oriented towards the 
prevailing wind direction during the heating season.
The outside air connection will supply the demands of 
the pellet appliance, but consideration must be given to 
the total house demand. House demand may consume 
some air needed for the stove, especially during a power 
failure. It may be necessary to add additional ventilation 
to the space in which the pellet appliance is located. 
Consult with your local HVAC professional to determine 
the ventilation demands for your house.
The  outside  air  kit  consists  of  a  flue  stub  pipe, 
fiberglass  gasket,  silicone  gasket,  intake  box  and  a 
section of flex pipe. 
An adjustable chimney intake extension, part # 1-00-
674104 is available to be used on masonry chimneys 
only. 
To install outside air, use kit part number 1-00-774280. 
Follow  the  installation  instructions  provided  with  the 
kit.
Vent Configurations:
To reduce probability of reverse drafting during 
shut-down conditions, Hearth & Home Technologies 
strongly recommends:
• Installing the pellet vent with a minimum vertical 
run of five feet, preferably terminating above the roof 
line.
• Installing the outside air intake at least four feet 
below the vent termination.
To prevent soot damage to exterior walls of the 
house and to prevent re-entry of soot or ash into the 
house:
• Maintain specified clearances to windows, doors, 
and air inlets, including air conditioners.
• Vents should not be placed below ventilated 
soffits. Run the vent above the roof.
• Avoid venting into alcove locations.
• Vents should not terminate under overhangs, 
decks or onto covered porches.
• Maintain minimum clearance of 12 inches from 
the vent termination to the exterior wall. If you see 
deposits developing on the wall, you may need to 
extend this distance to accommodate your installation 
conditions.
Hearth & Home Technologies assumes no 
responsibility for, nor does the warranty extend 
to, smoke damage caused by reverse drafting 
of pellet appliances under shut-down or power 
failure conditions.
Do  not connect this unit to any air 
distribution duct or system.