Pellets or Corn/Pellet Mixture Only                                           3-90-775                                                                           Save These Instructions
                         P35i Fireplace Insert
D.  Before Your First Fire
•  Be sure the appliance is installed properly and that 
all safety requirements have been met. Pay par-
ticular attention to the clearances to combustibles, 
floor protection and the venting instructions.
•  Test your smoke detector(s) and CO detector(s) to 
the specifications of the manufacturer.
•  Double check that the ash pan and internal firebox 
are empty.
•  Be sure to read this entire manual.
F.  Starting a Fire - "MANUAL"
1.  With the mode selector in the "OFF" position, and 
the Feed Adjuster 
NOT on "Test", plug the power 
cord into a properly grounded receptacle.
2.  Fill the hopper with DRY fuel. 
3.  Turn the FEED ADJUSTER dial to "Test". This will 
run the feed motor for one minute. If you begin to 
see fuel entering the burn pot, you can stop the 
test cycle. Return to #4 or #5 to start out.
4.  Turn the mode selector dial to the desired mode. 
This will start the combustion blower operating. 
If Room Temp is selected, be sure to turn the 
temperature dial above the current room tem-
perature.
5.  Fill the burn pot with a mixture of wood pellets and 
starting gel.
6.  Light the starting gel with a match, and close the 
door. 
7.  Only after the ESP temperature increases, will the 
feeder start operating to increase the fire size.
NEVER APPLY STARTING GEL TO THE FUEL IN 
THE BURN POT WITHOUT THE COMBUSTION 
BLOWER OPERATING.
WARNING
"NEVER USE GASOLINE, GASOLINE-TYPE 
LANTERN FUEL, KEROSENE, CHARCOAL 
LIGHTER FLUID, OR SIMILAR LIQUIDS TO 
START OR "FRESHEN UP " A FIRE IN THIS 
HEATER.  KEEP ALL  SUCH  LIQUIDS  WELL AWAY 
FROM THE HEATER WHILE IN USE".
WARNING
TESTED AND APPROVED  FOR  USE  WITH  WOOD 
PELLETS OR A MIxTURE OF SHELLED CORN AND 
PELLETS ONLY. USE OF ANY OTHER TYPE OF FUEL 
WILL VOID THE APPLIANCE WARRANTY.
E.  Draft Test Procedure
•  Using a 9/16" wrench, remove the draft test port 
plug bolt, located to the left inside the firebox. This 
bolt threads downward through the outside of the 
body. Externally, the opened hole is located above 
the ash pan spring latch on the left.
•  Insert the 
draft meter 
hose into the 
test port.
•  Be sure the 
meter is ca-
pable of a scale 
between 0 and 
1 inch Water 
Column. Zero the 
meter if necessary, 
and be sure it is set 
up to read in negative 
pressure.
•  Be sure the ash pan, door, and hopper lid are all 
closed and latched. 
•  Turn the feed adjuster to "Test" mode.
•  During the first minute of test, the combustion 
blower will be on high. Record the high draft 
reading here ____________-W.C. The high draft 
should be above -0.5" W.C.  but no higher than -1" 
W.C.
•  After a minute, the combustion blower will go to 
low speed. Here you want to see a reading be-
tween -0.30" and -0.35". If necessary, adjust the 
draft voltage using the low draft adjustment screw 
on the circuit board (See Page 24). Clockwise 
will increase the draft and counter-clockwise will 
decrease it. 
•  Once set, record the low draft reading here:_____
______ -W.C.
•  Be sure and turn off of "Test" mode. Disconnect 
the meter and return the plug bolt to the test port.
The optimal method of operation is in Room Temp 
mode, with the Ignition switch set to Automatic.