P35i Fireplace Insert
NEVER CONNECT THIS UNIT TO A CHIMNEY 
FLUE SERVING ANOTHER APPLIANCE.
Installation and repair of this stove should be done 
by  a  competent  and  qualified  professional.    We 
recommend  that  the  stove  be  inspected  before 
use  and  at  least  annually  by  a  qualified  service 
person. Periodic cleaning is required throughout 
the heating season and at the end of each winter 
for the stove to work efficiently.  
SPECIAL NOTE: 
DUE  TO  ASH  BUILDUP,  IT  IS  STRONGLY 
RECOMMENDED  TO  HAVE  YOUR  STOVE 
PROFESSIONALLY CLEANED AND SERVICED 
ANNUALLY. THIS INCLUDES ALL PARTS OF 
THE  STOVE, AND  THE  VENTING  SYSTEM.
Carbon monoxide, referred to as CO, is a colorless, 
odorless gas that is produced during combustion of solid 
fuels. 
CO is toxic and can be fatal.
Even  though  this  stove  is  designed  to  be  as  safe 
as possible, it is recommended that you 
install a CO 
detector.  This  is  true  for  oil,  gas,  or  wood  burning 
products as well.
CO  is  not    specifically  heavier  or  lighter  than  air. 
Therefore, it is best to install the detector at table top level 
rather than on the ceiling like a smoke detector.
CO detectors are very sensitive and may sound an 
alarm for fumes other than CO or CO from sources other 
than the stove such as a car or lawn mower exhaust.
If the alarm sounds 
1. Increase house ventilation by opening windows or 
doors.
2. Make sure the stove doors and hopper lid are closed 
and latched.
3. Check stove for electrical power and normal opera-
tion.
4. Check vent for possible blockage or down-draft.
5. Check for false alarm.
Never use gasoline, lantern fuel, kerosene, charcoal 
lighter fluid, or similar liquids to start or “freshen up” a 
fire in this heater.  Keep all such liquids well away from 
the heater while it is in use.
2
 
Special Warnings and Notes
DO NOT CONNECT TO ANY AIR 
DISTRIBUTION DUCT OR SYSTEM.