  Installation 
Figure 1
Rear support
Main Body
Mantel top
Hardware
!
 
NOTE:  A 15 Amp, 120 Volt 
alternating current (VAC) circuit 
is required.  A dedicated circuit 
is preferred but not essential in 
all cases.  A dedicated circuit will 
be required if, after installation, 
the circuit breaker trips or fuse 
blows on a regular basis when the 
heater is operating.  Additional 
appliances on the same circuit 
may exceed the current rating of 
the circuit breaker.
 WARNINg:  Ensure the power 
cord is not installed so that it is 
pinched or against a sharp edge 
and ensure that the power cord is 
stored or secured to avoid tripping 
or snagging to reduce the risk 
of fire, electric shock or injury to 
persons.
 WARNINg: Construction 
and electrical outlet wiring must 
comply with local building codes 
and other applicable regulations 
to reduce the risk of fire, electric 
shock and injury to persons.
 WARNINg: Do not attempt 
to wire your own new outlets or 
circuits.  To reduce the risk of fire, 
electric shock or injury to persons, 
always use a licensed electrician.
(No assembly required for the 
flat wall mantel)
Corner Mantel Assembly
assemble the top of the 
1. 
mantel to the rear support 
using the supplied hardware.
using the supplied hardware 
2. 
assemble the top and rear 
support assembly to the main 
fireplace body (Figure 1).
Fireplace Installation
Make sure the unit’s Main 
1. 
ON/OFF switch is switched 
OFF (refer to operating 
instruction section).
Plug the unit into a 15 Amp, 
2. 
120 VAC outlet.  If the cord 
does not reach, you may use 
a No. 14 AWG minimum size 
extension cord rated for a 
minimum of 1875 Watts.