Harman Stove Company XL Benutzerhandbuch

Seite von 34
Installation
Only For Qualified Installers
Connecting the  
Optional Thermostat
 
If the optional thermostat is used, it must be plugged into 
the terminal strip located in the lower left front corner 
of the heater.
When installing a millivolt control system, use only a 
special  low  resistance  thermostat.  DO  NOT  USE A 
REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean, free from 
corrosion, and tight. Inspect connections periodically to 
confirm that no corrosion has built up over time.
When  properly  installed  and  maintained,  a  millivolt 
control system should give many years of trouble-free 
service.
It  is  important  to  use  the  proper  gauge  wire  for  the 
length used.
RECOMMENDED WIRE GAUGES
 
Maximum  
Wire  
 
Length  
Gauge 
  100’   
14 
  60’ 
 
16 
  40’ 
 
18
  25’ 
 
20
  15’ 
 
22
Thermostat
Remote Control
The button on the remote control can be used to turn 
the burner on and off.  
This remote uses an ultrasonic control method and does 
not need to be pointed directly at the fireplace.
A  hand  held  sending  unit,  receiving  unit,  mounting 
bracket and all wiring are included when you order the 
remote control.
Installation instructions are packed with remote kit. 
Burner Button
Part # 3-20-12080
Part # 1-00-7911
24