Harman Stove Company XL Benutzerhandbuch

Seite von 34
Maintenance
Removing the Glass Door
Remove door by pulling latches out as shown and pulling 
the bottom of the door out from the unit about 3 inches. 
Then lift the door slightly up and off the hooks. 
Replacing the Glass and Gasket
The  ShadowLight  XL  uses  part  no.  3-44-00539 
fiberglass gasket in the front door. Should it ever need 
replacement, use only the proper replacement gasket 
that is available from your Harman dealer. To replace 
the gasket, follow this procedure.
1. Lay glass front face down.
2.  Bend  the  four  tabs  up  far  enough  to  remove  the 
glass.
3. Remove glass from frame. Discard gasket.
4. Install new gasket around glass (thick side toward 
stove).
5. Place glass in frame.
6. Bend tabs to secure glass. Not too tight.
7. Reinstall glass door by placing the door on the hooks 
at the top of the opening as shown. swing the bottom of 
the door in to the unit. Close the two latches to secure 
the door.
Cleaning the Glass
The glass may be cleaned with ordinary household glass 
cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do not 
use abrasive cleaners on the glass.
Inspecting the Venting 
An  inspection  of  both  pipes  of  the  venting  system 
should be made during the annual service appointment. 
They must have no blockage and be in good condition. 
The  vent  manufacturer’s  instructions  may  provide 
specific suggestions or details on vent inspection. Any 
sections that are taken apart for the inspection must be 
reassembled and sealed as required.
Cleaning the Log Set and Firebox
During  the  annual  inspection  and  maintenance 
appointment, the service person should clean dust, lint, 
and any light accumulation from the logs and the firebox 
area. An extra-soft brush should be used on the logs as 
they are extremely fragile; a vacuum cleaner may be 
used on the firebox. If at any time the logs cannot be 
removed or installed without forcing, the cause must be 
found. The logs must never be forced.
A  qualified  service  technician  recommended  by  your 
Harman  dealer  should  conduct  an  annual  inspection 
and  maintenance  of  your  fireplace,  its  venting,  and 
the installation to keep it running safely and efficiently. 
The  following  procedures  should  be  performed  only 
by a qualified service person. The gas supply should 
be  turned  off  whenever  a  maintenance  procedure  is 
performed.
If the glass front, or front access door are removed for 
servicing, they must be replaced prior to operating the 
fireplace.
WARNING:  DO  NOT  OPERATE  THIS 
APPLIANCE  WITH  THE  GLASS  FRONT 
REMOVED,  CRACKED  OR  BROKEN. 
REPLACEMENT  OF  GLASS  SHOULD  BE 
DONE  BY  A  LICENSED  OR  QUALIFIED 
SERVICE PERSON. NEVER USE SUBSTITUTE 
MATERIALS.
DO NOT STRIKE OR SLAM GLASS.
25