  CAUTION:  Do  not  attempt 
to slide the viewing hole cover 
when the main burner is lighting, 
operating or hot.
3.  Set the heat level.
a) Press and turn control knob to the HIGH 
position, Burner will light immediately.
b) Press and turn control knob to the desired 
heat level. Note: While in use, burner flame 
should be mainly blue in appearance with a 
small amount of yellow.
IMPORTANT:
 Smoke and odor (not a gas odor) 
emission may occur in the first 15 minutes of use. 
Run heater at high setting for at least 15 minutes 
to eliminate this problem.
 WARNING: If you smell gas 
while in use, immediately press 
and  turn  control  knob  to  the 
"OFF"  position  to  shutdown 
heater.
STOP
1.  Press and turn control knob to the PILOT 
position. Burner will extinguish but pilot will 
stay on.
2.  To extinguish pilot, press and turn control 
knob to the OFF position.
3.  Turn off gas supply.
4.  Do  not  attempt  to  relight  the  heater  for  5 
minutes after propane/LP cylinder valve has 
been closed.
RESTART HEATER
1.  Turn gas control knob to the OFF position.
2.  Wait 5 minutes.
3.  Restart following Start procedure.
STORAGE
1.  Allow at least 45 minutes for heater to cool 
down after using.
2.  Store heater upright in a sheltered area away 
from inclement weather and dust.
3.  If  desired,  cover  heater  after  heater  has 
cooled.
4.  If heater is not to be used for an extended period 
of time, disconnect and remove propane/LP 
gas cylinder and store in accordance with the 
Standard for Storage and Handling of Liquefied 
Petroleum Gases, ANSI/INFPA 58.
SERVICING
To assure safety, proper function and longevity 
of the heater, regular maintenance is required. 
The frequency of maintenance will depend on the 
usage of the unit. Review the following concern-
ing the criteria for a properly functioning heater. 
Failing to follow proper, regular maintenance will 
void warranty.
A hazardous condition may result if a heater is 
used that has been modified or is not functioning 
properly. When the heater is working properly:
•  The flame is contained within the heater.
•  The flame is essentially blue with perhaps some 
yellow tipping.
•  There is no strong disagreeable odor, eye burn-
ing or other physical discomfort.
•  There is no smoke or soot internal or external 
to the heater.
•  There are no unplanned or unexplained shut 
downs of the heater.
The parts lists and wiring diagram show the heater 
as it was constructed. Do not use a heater which is 
different from that shown. In this regard, use only 
the hose, regulator and cylinder connection fitting 
(called a POL fitting) supplied with the heater. 
IMPORTANT:
  Do  not  use  alternates.  For  this 
heater,  the  regulator  must  be  set  as  shown  in 
Specifications. If there is any uncertainty about 
the regulator setting, have it checked. 
OPERATING INSTRUCTIONS