Desa P)T Benutzerhandbuch

Seite von 44
www.desatech.com
119426-01A
26
FRONT BURNER FLAME PATTERN
Figure 38 shows correct front burner flame pat-
tern. Figure 39 shows incorrect front burner flame 
pattern. The incorrect burner flame pattern shows 
yellow tipping at top of blue flame.
 WARNING: If yellow tipping 
occurs, your heater could pro-
duce increased levels of carbon 
monoxide. If front burner flame 
pattern  shows  yellow  tipping, 
follow instructions at bottom of 
this page. Yellow flame on rear 
burner is normal.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles are burned 
by heater, causing brief patches 
of orange flame.
If front burner flame pattern is incorrect, as shown 
in Figure 39
•  turn heater off (see To Turn Off Gas to Appli-
ance, page 21 [Thermostat-Controlled Models] 
or page 23 [Remote-Ready Models])
•  see Troubleshooting, page 28
INSPECTING bURNERS
Continued
Figure 38 - Correct Front Burner Flame 
Pattern
Figure 39 - Incorrect Front Burner Flame 
Pattern 
Yellow Tipping At 
Top of Blue Flame 
CLEANING AND 
MAINTENANCE
  WARNING:  Turn  off  heater 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burners  and 
circulating  air  passageways 
of  heater  clean.  Inspect  these 
areas of heater before each use. 
Have  heater  inspected  yearly 
by  a  qualified  service  person. 
Heater may need more frequent 
cleaning  due  to  excessive  lint 
from carpeting, pet hair, bedding 
material, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INjECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt, 
lint and pet hair. Clean these air inlet holes prior to 
each heating season. Blocked air holes will create 
soot. We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.
We also recommend that you keep the burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local 
computer store, hardware store or home center 
may carry compressed air in a can. You can use a 
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on 
the can. If you don’t follow directions on the can, 
you could damage the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect burner, pilot and primary air inlet holes 
on injector holder for dust and dirt (see Figure 
40, page 27).
3.  Blow air through the ports/slots and holes in 
the burner.