Desa P)T Benutzerhandbuch

Seite von 44
www.desatech.com
119426-01A
27
4.  Check the injector holder located at the end 
of the burner tube again. Remove any large 
particles of dust, dirt, lint or pet hair with a 
soft cloth or vacuum cleaner nozzle.
5.  Blow air into the primary air holes on the 
injector holder.
6.  In case any large clumps of dust have now been 
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about 
2" from where the pilot flame comes out of the 
pilot assembly (see Figure 41). With the unit off, 
lightly blow air through the air inlet hole. You may 
blow through a drinking straw if compressed air 
is not available.
CLEANING AND 
MAINTENANCE
Continued
LOGS
•  If you remove logs for cleaning, refer to Install-
ing Logs, page 18, to properly replace logs.
•  Replace log(s) if broken or chipped (dime-sized 
or larger).
MAIN BURNER
Periodically inspect all burner flame holes with 
the heater running. All slotted burner flame holes 
should be open with yellow flame present. All 
round burner flame holes should be open with a 
small blue flame present. Some burner flame holes 
may become blocked by debris or rust, with no 
flame present. If so, turn off heater and let cool. 
Remove blockage, blocked burner flame holes 
will create soot.
Figure 40 - Injector Holder On Outlet 
Burner Tube
Burner 
Tube
Injector Holder
Primary Air 
Inlet Holes
Ports/Slots
Figure 41 - Pilot Inlet Air Hole (Your pilot 
may vary from pilot shown)
Pilot Air 
Inlet Hole
Pilot Assembly
WIRING DIAGRAM
(Remote-Ready Models Only)
Thermopile