Haier HSU-24HEK03/R2 Benutzerhandbuch

Seite von 29
3
Operation
   Air Flow Direction Adjustment
AUTO
COOL
DRY
FAN
HEAT
2.Select operation mode
Press FAN button. For each press, fan speed 
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will 
decrease  rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
 Press ON/OFF on the remote controller, unit starts.
Base  Operation
Remote controller
Vertical flap
Pos.1 blank Pos.2
Pos.3
Pos.4
(Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote 
         memorize the previous 
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur 
adjusted to left or 
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency operation and test operation
at air outlet if all vertical louvers are 
right.
mode ,
controller will automatically
Note:
set swing position.
changes as
'
Operation
Mode
AUTO
Remote
Controller
Note
COOL
DRY
HEAT
FAN
In DRY mode , when room temperature becomes
lower than temp.setting+2
o
C, unit will run 
intermittently at LOW speed regardless of FAN 
Under the mode of auto operation, air conditioner 
will automatically select Cool or Heat operation
according to room temperature
to AUTO the air conditioner automatically adjusts
temperature.
When FAN is set 
the fan speed according to room
In FAN operation mode , the unit will not operate in
COOL or HEAT mode  but only in  FAN mode ,
AUTO is not available in FAN mode. And temp.
setting is disabled  In FAN mode, sleep operation 
 setting.
is not available. 
AUTO
LO
MED
HI
ON/OFF
FAN
MODE
LOCK
RESET
SWING
TIMER
CLOCK
SET
SLEEP
POWER/SOFT
LIGHT
test operation
 switch
Pi
Pi
Emergency Operation:
Use this operation only when the remote controller is defective 
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation. 
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in 
the following modes:
    Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
  Above 23
o
C
  Below 23
o
C
 
23
o
C
 26
o
C
No
AUTO
AUTO
COOL
HEAT
No
Pi
emergency
operation switch
It is impossible to change the settings of temp. and fan speed,It 
is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the 
Test operation:
Use this switch in the test operation when the room
normal operation.
 your finger from the switch: the cooling
Continue to press the test operation 
switch for more than 5 seconds . After
 you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
In HEAT mode, warm air will blow out after a short 
period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically 
adjusts the fan speed according to room temperature.