CHECKING GAS PRESSURE 
AND
 CONNECTING REMOTE RECEIVER 
The heater gas inlet connection is 3/8" NPT at the valve. The 
inlet is located on left side of stove. Remove front control plate 
to better access the inlet. 
When tightening up the joint to the valve, hold the valve securely 
with a wrench to prevent movement.
Test all gas joints from the gas meter to the heater valve for 
leaks using a gas analyzer or soap and water solution after completing connection.  DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to HIGH.
Connecting directly to an unregulated 
propane/L.P.G.  tank  can  cause  an 
explosion.
W
ARNING
MILLIVOLT CONTROL (FIGURE 5)
The valve regulator controls the burner pressure which should 
be checked at the pressure test point.
If outlet pressure is low, check inlet pressure against data plates 
or manual. 
Turn captured slotted screw counter clockwise 2 or 3 turns and 
then place tubing to pressure gauge over test point (Use test 
point “OUT” closest to control knob). After taking pressure 
reading, be sure and turn captured screw clockwise firmly to 
re-seal. Do not over torque. Check for gas leaks.
NOTE: Remove control panel to access gas valve 
and ignitor battery module. 
Figure 5 - Pressure Test Point Location
Milli-Volt Control 
Test Port “OUT”
CONNECTING REMOTE RECEIVER
   1.  Remove  cover  on  control  panel  to  show  opening  for 
remote receiver. See Figure 6. 
   2.  Cut cable to length (approximately 12") for placement in 
the fireplace. 
   3.  Strip back 
1
/
4
" of the insulation from both ends of each 
wire. 
   4.  Connect two .25 female connectors to the wires at one 
end of the cable.  
   5.  Insert the opposite ends of the wires into the receiver wire 
terminals and tighten the screws. 
   6.  Connect the connectors to the two .25" male connectors 
located on the left side when facing the unit (Figure 6). 
Do not let the wire touch the grate or burners. 
   7.  Slide  remote  receiver  in  the  opening  of  control  panel. 
Use two screws provided to attach remote receiver to the 
control panel. See Figure 6. 
   8.  Replace Cover. See Figure 6. 
NOTE: Do not place remote in combustion 
chamber. 
Figure 6 - Installing Remote Receiver 
Remote Receiver 
Cover