Monessen Hearth C2801VF Benutzerhandbuch

Seite von 28
12                                                                                                                                                                                 
45D0080
45D0080                                                                                                                                                                                                    
13
ELECTRICAL WIRING (MILLI-VOLT)
The milli-volt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110 VAC TO OPERATE.
Label all wires prior to 
disconnection when 
servicing controls. Wiring 
errors can cause improper 
and dangerous operation. 
Verify proper operation 
after servicing.
CAUTION 
On/Off
Switch
On/Off
Switch
ODS 
Pilot
Wall
Switch
Optional Wall
Switch, Wall Thermostat,
Thermostat Sensor or
Remote
ODS Pilot
Millivolt 
Valve
Spade Terminal
3
1
2
CONNECTION
  1  =  TP
  2  =  TP, TH
  3  =  TH
Figure 7 - Wiring Diagram
CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT
   1.  Use 18 awg, two-wire cable, 15 feet maximum length.
   2.  At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to 
TP/TH and one wire to TH, or connect the wall switch/thermostat to the two male (0.25") terminals on the left side of 
the unit. The color of the wires does not matter.
                                                      CONNECT
  CHECK                TO                      METER            THERMOSTAT          METER
    TEST               TEST                 LEADS TO           CONTACTS           READING
                                                     TERMINALS                                      SHOULD BE
       A              COMPLETE                 2 & 3                  CLOSED             MINIMUM 
                                                        SYSTEM                                              175mv
       B            THERMOPILE               1 & 2                     OPEN                  500mv 
                         OUTPUT                                                                         OR MORE 
A.  COMPLETE MILLIVOLT SYSTEM CHECK 
("A" Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main Burners should turn ON)
       a.  If the reading is more than 175 millivolts and the automatic valve still does not come on - replace the valve.
       b.  If the closed circuit reading ("A" reading) is less than 175 millivolts, determine cause for low reading - proceed as 
follows:
B.  THERMOPILE OUTPUT READING CHECK 
(“B” Reading - Thermostat contacts OPEN - Main burner OFF)
       Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then replace pilot. 500 millivolts 
minimum. If the minimum millivolt reading is not obtainable, replace pilot.
CHECKING SYSTEM OPERATION
The millivolt system and individual compo-
nents may be checked with a millivolt meter 
having  a  0-1000mv  range.  Conduct  each 
check shown in chart by connecting meter 
test leads to terminals as indicated.
Switch