Monessen Hearth C2801VF Benutzerhandbuch

Seite von 28
16                                                                                                                                                                                 
45D0080
45D0080                                                                                                                                                                                                    
17
Glowing 
Embers 
Figure 15 - Correct appearance of 
Embers and Rear Flame 
FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. 
In addition, periodically check the flames visually during operation.
CHECKING PILOT FLAME
The pilot flame must always be present when the heater is in operation. 
It should just touch the top of the ther-
mocouple tip for natural. See Figure 13 for correct pilot flame. 
If the pilot flame does not touch the thermocouple, then the burners cannot function reliably. See Figure 14 for incorrect 
shape of pilot flame.
MILLI-VOLT CONTROL
Figure 13 - Correct Appearance of Pilot Flame
Figure 14 - Incorrect Appearance of Pilot Flame
Thermocouple
for Natural  
Thermocouple
for LP
Thermocouple
for LP
Thermocouple
for Natural 
CHECKING BURNER FLAME
In normal operation at full rate after 15 minutes, the follow-
ing flame appearances should be observed:
The left and right rear flames should be yellow and extend 1"-2" above 
the log top surfaces. The yellow flames should not contact the logs. 
There should be glowing embers on the front surface of the middle 
log. Note: The flames and embers will be an opaque orange 
color during the burn off time. 
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow 
fans to blow directly into the stove. Do not place a blower inside the 
burn area of the stove. Ceiling fans may create drafts that alter flame 
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or 
bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during 
the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary 
occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventila-
tion by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight 
and will disappear with continued use.