OPERATING INSTRUCTIONS
   1.   STOP! Read the safety information label.
   2.   Make sure the manual shutoff valve is fully open.
   3.   This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo 
ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions”, page 21.
   4.   Turn gas control knob clockwise 
 to the OFF position, set the thermostat to the lowest setting and 
turn ON/OFF switch to OFF position.
   5.   Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! 
Follow the instructions under “What To Do if You Smell Gas,” page 16. If you don't smell gas, go to next 
step.
   6.   From OFF position, turn the gas control knob counterclockwise 
 to IGN position. Push in control 
knob for 5 seconds. NOTE: If you are running the heater for the first time, it will be necessary 
to press in the control knob for 30 seconds or longer to allow air to bleed out of the gas 
piping. 
   7.   With the control knob pushed in, the battery powered ignition will light the pilot.
   8.   Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting 
off the gas while the probe is warming up. Release the control knob.
   9.   Turn gas control knob counterclockwise 
 to the ON position.
 10.   After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON 
position or adjust thermostat to desired setting. 
NOTE: To use the optional thermostat function (if 
installed), the control knob must be set to “ON” and the ON/OFF Switch must be in the “OFF” 
position. 
 11.   If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and call your 
service technician or gas supplier.
Figure 17 - Pilot 
 
TO TURN OFF GAS TO HEATER
 
   1.   Turn control knob clockwise 
 to OFF position to completely shut off the heater.
   2.    If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
   3.   If applicable: Turn off all electric power to the heater.
Figure 18 - Control Cover Plate for Milli-Volt 
Hi/Lo Control 
Ignitor/Pilot Control
 MILLI-VOLT CONTROL LIGHTING INSTRUCTIONS 
On/Off Switch
(Located on Side 
of Stove)