NOTICE
Accessories  for  woodstoves  for  clearance  reduction  have
been  developed  by  many  manufacturers.  If  not  following
the  methods  of  the  installation  codes,  be  sure  that  any
accessory  you  choose  has  been  tested  by  an  independent
laboratory  and  carries  the  laboratory’s  testing  mark.
Make  sure  to  follow  all  of  the  manufacturer’s
instructions.
Always  contact  your  local  building  inspector  or  fire
officials  about  restriction  and  requirements  in  your  area.
Reminder,  it  is  the  local  officials  who  have  final  authority
in  the  installations  approval.
ALCOVE
The  F  3  CB  is  approved  for  installations  in  an
unprotected and protected ALCOVE provided the
following guidelines are followed:  Stoves must be
positioned as shown in figures 13 or 
14.
MINIMUM UNPROTECTED ALCOVE:
Assumes-
top exit, single wall pipe, and stove’s rear heatshield.
Minimum alcove width  =  71”  
(1805mm)
Maximum alcove depth  =  40”  
(1015mm)
Height above the top of the stove = 68” 
(1730mm)
Top vent/vertical-  assumes the connector pipe is
exiting off the top of the stove and traveling vertically.
If top vented to any horizontal runs  –the stove’s
position is dictated by the connector pipe clearances.
MINIMUM PROTECTED ALCOVE:
Assumes-
top exit, double wall pipe, and stove’s rear heatshield.
Minimum alcove width  =  35”  
(890mm)
Maximum alcove depth  =  24”  
(610mm)
Height above the top of the stove =  40” 
(1015mm)
In a PROTECTED alcove installation both side walls
and rear wall  must be protected per NFPA 211 or
CAN/CSA-B365.    The  wall  protection  must  be
elevated 1” from the floor  and at least 1” off the
combustible wall to allow  for an air-flow.
FIGURE  13
REAR EXIT ALCOVE INSTALLATIONS:
Unprotected alcove:  assumes single wall pipe and
stove’s rear heatshield.
Minimum alcove width = 71” (1805 mm)
Maximum alcove depth = 40” (1015mm)
Alcove ceiling above top of stove = 68” (1730mm)
Protected  alcove:    assumes  double  wall  pipe  and
stove’s rear heatshield.
Minimum alcove width = 35” (890mm)
Maximum alcove depth = 30” (760mm)
Alcove ceiling above top of stove = 40” (1015mm)
FIGURE  14
35”  min.
890mm
  max.  depth
  24”  (610mm)
150mm
150mm
10”
255mm
71”  min.
(1805mm)
max.  depth
40”  (1015mm)
24”
610mm
24”
610mm
25”
635mm
13
Alcove floor protection must be: a UL/ULC or WHI
listed hearth board OR a non cmbustible material with
a minimum R value of 1.1.