STOVE CLEARANCES UNPROTECTED SURFACES PROTECTED SURFACES
TOP VENT/VERTICAL
per NFPA 211 or CAN/CSA-B365-M
SIDE
REAR
CORNER SIDE
REAR
CORNER
Rear heatshield with
24"
25"
18"
10"
14"
10"
Single wall pipe
610 mm
635 mm
460 mm
255 mm
355 mm
255 mm
Rear heatshield with
18"
10"
14"
6"
6"
6"
Double wall pipe or shields 460 mm
255 mm
355 mm
150 mm
150 mm
150 mm
STOVE CLEARANCES UNPROTECTED SURFACES PROTECTED SURFACES
REAR VENT/HORIZONTAL
per NFPA 211 or CAN/CSA-B365-M
SIDE
REAR
CORNER SIDE
REAR
CORNER
Rear heatshield with
24
25
20
10
25
18
Single wall pipe
610 mm
635 mm
510 mm
255 mm
635 mm
460 mm
Rear heatshield with
18
14
17
6
6
6
Double wall pipe or shields 460 mm
355 mm
430 mm
150 mm
150 mm
150 mm
CONNECTOR
UNPROTECTED SURFACE PROTECTED SURFACE
CLEARANCES
per NFPA 211 or CAN/CSA-B365-M
Single wall pipe-
vertical installations
18" (460mm)
6" (150mm)
Double wall pipe-
vertical installations
pipe mfgr. listing
pipe mfgr. listing
Single wall pipe-
horizontal installations
18 (460mm)
9 (230mm)
Double wall pipe-
horizontal installations
pipe mfgr. listing
pipe mfgr. listing
VERY IMPORTANT:
Top Vent - Vertical: assumes the connector pipe
runs from the top of the stove and travels vertically.
If top vented to a horizontal run, the stove position
is dictated by the connector pipe clearances.
Rear Vent - Horizontal: assumes the connector
pipe extends from the rear of the stove and travels
horizontally to the chimney. If rear vented to a
vertical run, the stove position is dictated by the
connector pipe clearances.
Dimensions in Inches represent U.S. requirements.
Dimensions in Millimeters represent Canadian
requirements.
WALL PROTECTION IS DISCUSSED IN FURTHER
DETAIL ON PAGE 12 OF THIS MANUAL.
DETAIL ON PAGE 12 OF THIS MANUAL.
F 3 CB WOODSTOVE CLEARANCES*
MANTEL CLEARANCES
A = Top to Mantel
34
860 mm
B = Top to Top Trim
20
510 mm
C = Side to Side Trim
13
330 mm
D = Side to Side Wall:
24
610 mm