IMPORTANT
SAVE THESE 
INSTRUCTIONS
The REGENCY Room Sealed Freestanding 
Gas Stove must be installed in accordance 
AG601 and NZS 5261 and with these instruc-
tions. Carefully read all the instructions in this 
manual fi rst. Consult the building authority 
having jurisdiction to determine the need for a 
permit prior to starting the installation.
Note: Failure to follow the instructions 
could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or property 
damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.
Note: These instructions take precedence 
over Simpson Dura-Flue instruc-
tions.
SPECIFICATIONS
Fuels:  F39-NG is approved for use with NG.
 
 
F39-LPG is approved for use with lique-
fi ed petroleum gases (LPG).
Electrical:  240V  A.C. system.
Circulation Fan:  Variable speed, 125/75.
Log Sets:  Ceramic fi bre, 7 per set.
Flue System: Coaxial (6-5/8" outer / 4" inner 
liner) rigid fl ue and termination cap.
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however, we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:
INSTALLATION
COMPARTMENT, BURNERS AND 
CIRCULATING AIR PASSAGE-
WAYS OF THE APPLIANCE BE 
KEPT CLEAN.
DUE TO HIGH TEMPERATURES, 
THE APPLIANCE SHOULD BE 
LOCATED OUT OF TRAFFIC AND 
AWAY FROM FURNITURE AND 
DRAPERIES.
WARNING: FAILURE TO INSTALL 
THIS APPLIANCE CORRECTLY 
WILL VOID YOUR WARRANTY 
AND MAY CAUSE A SERIOUS 
HOUSE FIRE.
CHILDREN AND ADULTS SHOULD 
BE ALERTED TO THE HAZARDS 
OF HIGH SURFACE TEMPERA-
TURES, ESPECIALLY THE FIRE-
PLACE GLASS, AND SHOULD 
STAY AWAY TO AVOID BURNS 
OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD 
BE CAREFULLY  SUPERVISED 
WHEN THEY ARE IN THE SAME 
ROOM AS THE APPLIANCE.  
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE. 
INSTALLATION AND REPAIRS 
SHOULD BE DONE BY AN AU-
THORIZED SERVICE PERSON. 
THIS APPLIANCE SHOULD BE IN-
STALLED, REPAIRED, INSPECT-
ED BEFORE USE AND AT LEAST 
ANNUALLY BY AN AUTHORIZED 
SERVICE PERSON.  MORE FRE-
QUENT CLEANING MAY BE RE-
QUIRED DUE TO EXCESSIVE LINT 
FROM CARPETING, ETC.  IT IS 
IMPERATIVE THAT THE CONTROL 
tured home installations, see page 9 for the 
required fl ue arrangements. If installed into a 
manufactured home the unit must be bolted 
down to the fl oor. 
4)  This appliance is Listed for bedroom  instal-
lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
5)  This appliance is Listed for Alcove installa-
tions, maintain minimum Alcove clearances 
as follows,   minimum width of 48" (1219mm), 
a maximum depth of 36" (914mm), and 
minimum ceiling height of 64"(1626mm).
6)  We recommend that you plan your instal-
lation on paper using exact measurements 
for clearances and fl oor protection before 
actually installing this appliance.  Have an 
authorized building inspector review your 
plans before installation.
GENERAL SAFETY 
INFORMATION
1)  The appliance shall be installed in accord-
ance with the manufacturer's installation 
instructions,local gas fi tting regulations, 
municipal building codes, water supply 
regulations, electrical wiring regulations, 
with AG 601 (AGA gas installation code) 
NZS 5261 (New Zealand)
2)  Installation and repair should be done 
ONLY by an authorised person.  
3)  DO NOT CONNECT TO MASONARY 
FLUE.
4)  This appliance must be connected to the 
specifi ed fl ue and termination cap to the 
outside of the building envelope. Never 
fl ue to another room or inside a building. 
Make sure that the fl ue is fi tted as per 
Flueing instructions.
5)  Inspect the fl ueing system annually for block-
age and any signs of deterioration.   
6)  Flueing terminals shall not be recessed into 
a wall or siding.
7)  Any safety glass removed for servicing must 
be replaced prior to operating the appli-
ance.
8)  To prevent injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.
9)  Wear gloves and safety glasses for protection 
while doing required maintenance.
1)  Provide adequate clearances for servicing, 
proper operation and around the air openings 
into the combustion chamber. 
2)  The appliance may be installed on a fl at, 
solid, continuous surface (e.g. wood, metal, 
concrete). This may be the fl oor, or it can be 
raised up on a platform to enhance its visual 
impact. The appliance may be installed on 
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's 
metal pedestal base extends the full width 
and depth of the appliance. The Regency
®
 
Room Sealed Freestanding Gas Stove can 
be installed in a wide variety of ways and will 
fi t nearly any room layout. It may be installed 
in a recessed position, framed out into the 
room, or across a corner.
3) The 
Regency
®
 Room Sealed Freestanding 
Gas Stove  is approved for alcove installa-
tions, which meet the clearances listed on 
page 7. This unit is approved for manufac-