MACHINE TROUBLESHOOTING 
SABER (SC)   86038350   01/29/07 
4-10
 
 
PROBLEM 
CAUSE 
SOLUTION 
Little or no solution flow to the 
floor 
Solution tank empty 
Fill solution tank 
  
Solution flow turned off or 
set too low 
Turn on or increase flow 
setting 
 
Solution strainer plugged 
Clean solution strainer 
  
Solution hoses obstructed 
Clear obstruction from 
hose 
  
Solution solenoid valve 
obstructed or stuck 
(traction model only) 
Clean or replace 
No power to machine 
Battery disconnected 
Check all battery cable 
connections 
 
Emergency shut-off 
activated (traction model 
only) 
Reset 
  
Battery connections 
corroded 
Clean connections 
  
Faulty main contactor 
Replace contactor 
  
Faulty power switch 
Replace switch 
Little or no propel (traction model  
Low battery charge 
Charge batteries 
only) 
Machine turned on with 
directional control button(s) 
not in neutral 
Allow control button to 
return to neutral. Restart 
 
Controller overheated 
Allow cool down period 
 
Loose connection 
Check motor wires and 
connection