MACHINE TROUBLESHOOTING 
SABER (SC)   86038350   01/29/07 
 4-9 
 
 
PROBLEM 
CAUSE 
SOLUTION 
Poor or no water pick-up 
Debris caught on squeegee
Remove debris 
  
Worn squeegee blades 
Replace squeegee blades 
  
Vacuum hose clogged 
Clear obstruction from 
hose 
  
Vacuum hose disconnected 
from squeegee or recovery 
tank 
Reconnect vacuum hose 
  
Vacuum hose damaged 
Replace vacuum hose 
  
Vacuum motor inlet screen 
dirty 
Clean inlet screen 
  
Recovery tank not sealed 
Check vacuum motor 
position. Replace 
damaged seal. 
  
Foam filling recovery tank 
Empty recovery tank 
Use less or different 
detergent 
Use defoamer 
Vacuum motor does not run, or 
runs slowly 
Recovery tank full 
Drain recovery tank 
 
Circuit breaker tripped 
Reset circuit breaker 
  
Loose connection 
Check motor wires and 
connections 
  
Faulty vacuum contractor 
Replace contactor 
  
Worn vacuum motor 
brushes 
Replace brushes, check 
commutator 
Poor scrubbing performance 
Debris caught in scrub 
brush 
Remove debris 
 
Worn brush or pad 
Replace brush or pad 
 
Improper detergent, brush 
or pad used 
Contact equipment or 
application specialist 
 
Low scrub brush down 
pressure 
Increase brush pressure 
(traction model only) 
 
Low battery charge 
Charge batteries 
Brush motor does not run, or runs 
slowly  
Circuit breaker tripped 
Reset circuit breaker 
 
Loose connection 
Check motor wires and 
connection 
 
Faulty brush motor 
contactor 
Replace contactor 
 
Worn brush motor brushes 
Replace brushes, check 