8
Status of the 
appliance
8.1
Introduction
Topics covered in this chapter:
;
8.2
Operating modes
When running, the appliance has four basic operating 
modes, namely:
OFF
ON
EXTRA
PROG
8.2.1
OFF
In this mode, the frost protection is activated. The 
figure shows the display with the following information:
line one: the text OFF;
line two: the time, the day and alternately
 T
and T
net
.
lines three and four: the text 
FROST PROTECTION ACTIVATED
.
8.2.2
ON
In this mode, the appliance continually responds to the 
hot water demand. The figure shows the display with 
the following information:
line one: the text ON;
line two: the time, the day and alternately
 T
and T
net
.
line three: the programmed water temperature 
T
set
;
line four: blank when the appliance is idle, or 
depending on the heating cycle
displays a text such as 
HEAT DEMAND
.
8.3
EXTRA
In this mode, one extra period is programmed and 
activated. In this mode, the OFF orPROG mode is 
temporarily overruled to fulfil a single period of demand. 
Once the period has passed, the appliance automatically 
returns to the previous operating mode. The figure shows 
the display with the following information:
line one: the text EXTRA;
line two: the time, the day and alternately
and T
net
;
line three: the switch-on time, and the related 
water temperature setting;
line four: the text PERIOD ACTIVATED.
8.3.1
PROG
In this mode a preset week program is active, and the 
appliance responds continually to demand within the 
time periods set in the week program. There are two 
distinct situations possible in this mode:
1. The current time falls within a set time period 
of the week program.
The figure shows the display with the following 
information:
-
line one: the text PROG;
-
line two: the time, the day and T
and T
net
 
alternately
;
-
line three: the next scheduled switch-off time 
and the water temperature T
set
 of the active 
period;
-
line four: is empty, or depending on the 
heating cycle
, a text such as HEAT DEMAND.
OFF
13:45 Thursday
6ÉC
FROST PROTECTION
ACTIVATED
ON
13:45 Thursday
67ÉC
Tset 75ÉC
EXTRA
12:30 Thursday
76ÉC
TH 12:45
Tset 75ÉC
PERIOD ACTIVATED
PROG
10:00 Monday
76ÉC
MO 11:15
Tset 75ÉC
  
PROG
12:00 Monday
76ÉC
MO 11:15