Starting and running
9.1
Introduction
Topics covered in this chapter:
.
Note
The first time the appliance is started, you must 
enter
 the 
settings of the solar heating system 
9.2
Starting the appliance
Start the appliance as follows:
1. Fill the appliance
.
2. Open
 the manual gas 
valve.
3. Switch on the power to the appliance using the 
isolator between the appliance and the power 
supply. 
4. Switch the electronic controller ON by setting the 
ON/OFF switch to position I.
The display will now show INTERNAL CHECK for 
about 10 seconds, and will then go to the main menu.
Note
The first time the appliance is started, you must 
 the heating fluid type of the solar 
heating system.
5. Press once on the blue arrow ( ) to position the 
cursor beside ON, then press 
:
6. Confirm the selection START OPERATION with 
.
The appliance is now in "ON mode". If there is a 
heat demand, the appliance will run through the 
heating cycle
If the heating cycle is not run, then there is no 
demand; should this happen, then Tset will 
probably need to be set
9.3
The appliance's heating cycle
The appliance's heating cycle is activated as soon as 
the measured water temperature (T
net
) falls below the 
threshold value (T
set
). This threshold value depends 
on the currently selected appliance operating mode. 
For example, if the appliance is in "OFF mode" (frost 
protection), then this value is 5°C. If the appliance is in 
"ON mode", then this threshold value is selectable, for 
example, 65°C.
The heating cycle runs in turn through the following 
states:
1. HEAT DEMAND;
2. PRE-PURGE;
3. PRESSURE SWITCH;
4. PRE-GLOW;
5. IGNITION;
6. RUNNING;
7. POST-PURGE.
INTERNAL CHECK
MENU
 »OFF
^ ON
È WEEK PROGRAM
a
a
 »START OPERATION
^ CHANGE SETPOINT
È
Tset=65ÉC
a