coMMonwealth of Massachusetts
For all side wall terminated, horizontally vented power vent, direct 
vent, and power direct vent gas fueled water heaters installed in 
every  dwelling,  building  or  structure  used  in  whole  or  in  part  for 
residential  purposes,  including  those  owned  or  operated  by  the 
Commonwealth and where the side wall exhaust vent termination 
is less than seven (7) feet above finished grade in the area of the 
venting, including but not limited to decks and porches, the following 
requirements shall be satisfied:
InstallatIon of carbon MonoXIde detectors
At  the  time  of  installation  of  the  side  wall  horizontal  vented  gas 
fueled equipment, the installing plumber or gasfitter shall observe 
that  a  hard  wired  carbon  monoxide  detector  with  an  alarm  and 
battery  back-up  is  installed  on  the  floor  level  where  the  gas 
equipment is to be installed. In addition, the installing plumber or 
gasfitter shall observe that a battery operated or hard wired carbon 
monoxide  detector  with  an  alarm  is  installed  on  each  additional 
level of the dwelling, building or structure served by the sidewall 
horizontal vented gas fueled equipment. It shall be the responsibility 
of the property owner to secure the services of qualified licensed 
professionals  for  the  installation  of  hard  wired  carbon  monoxide 
detectors.
In  the  event  that  the  side  wall  horizontally  vented  gas  fueled 
equipment is installed in a crawl space or an attic, the hard wired 
carbon monoxide detector with alarm and battery back-up may be 
installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not be 
met at the time of completion of installation, the owner shall have 
a period of thirty (30) days to comply with the above requirements 
provided that during said thirty (30) day period, a battery operated 
carbon monoxide detector with an alarm shall be installed.
approved carbon MonoXIde detectors
Each  carbon  monoxide  detector  as  required  in  accordance  with 
the above provisions shall comply with NFPA 720 and be ANSI/UL 
2034 listed and CSA certified.
sIGnaGe
A metal or plastic identification plate shall be permanently mounted 
to the exterior of the building at a minimum height of eight (8) feet 
above grade directly in line with the exhaust vent terminal for the 
horizontally  vented  gas  fueled  heating  appliance  or  equipment. 
The sign shall read, in print size no less than one-half (1/2) inch 
in size, 
“Gas vent dIrectlY below. Keep clear of all 
obstructIons.”Inspection The state or local gas inspector of 
the  side  wall  horizontally  vented  gas  fueled  equipment  shall  not 
approve  the  installation  unless,  upon  inspection,  the  inspector 
InstallatIon requIreMents - coMMonwealth of Massachusetts
observes  carbon  monoxide  detectors  and  signage  installed  in 
accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.
eXeMptIons
The  following  equipment  is  exempt  from  248  CMR  5.08(2)(a)1 
through 4:
1.  The  equipment  listed  in  Chapter  10  entitled  “Equipment  Not 
Required To Be Vented” in the most current edition of NFPA 54 
as adopted by the Board; and
2.  Product  Approved  side  wall  horizontally  vented  gas  fueled 
equipment  installed  in  a  room  or  structure  separate  from  the 
dwelling,  building,  or  structure  used  in  whole  or  in  part  for 
residential purposes.
Manufacturer requIreMents - Gas 
equIpMent ventInG sYsteM provIded
When the manufacturer of Product Approved side wall horizontally 
vented gas equipment provides a venting system design or venting 
system components with the equipment, the instructions provided 
by  the  manufacturer  for  installation  of  the  equipment  and  the 
venting system shall include:
1.  Detailed instructions for the installation of the venting system 
design or the venting system components; and
2.  A complete parts list for the venting system design or venting 
system.
Manufacturer requIreMents - Gas 
equIpMent ventInG sYsteM not provIded
When the manufacturer of a Product Approved side wall horizontally 
vented  gas  fueled  equipment  does  not  provide  the  parts  for 
venting the flue gases, but identifies “special venting systems,” the 
following requirements shall be satisfied by the manufacturer:
1.  The  referenced  “special  venting  system”  instructions  shall 
be  included  with  the  appliance  or  equipment  installation 
 instructions; and
 
2.  The “special venting systems” shall be Product Approved by the 
Board, and the instructions for that system shall include a parts 
list and detailed installation instructions.
A  copy  of  all  installation  instructions  for  all  Product  Approved 
side  wall  horizontally  vented  gas  fueled  equipment,  all  venting 
instructions,  all  parts  lists  for  venting  instructions,  and/or  all 
venting  design  instructions  shall  remain  with  the  appliance  or  
equipment at the completion of the installation.