Monessen Hearth BTU/Hr Benutzerhandbuch

Seite von 32
4                                                                                                                                                                                   
49D0090
49D0090                                                                                                                                                                                                      
5
NATURAL GAS
NOTE: An external regulator is required to reduce supply pressure to a maximum of 10
1
/
2
" W.C. on 
natural gas systems operating at higher pressure.
 
Thermostat Pressure                       
Regulator Pressure Setting: 4" w.c.         
Gas Inlet Pressure: 10
1
/
2
" w.c.                 
 
Min. 5" w.c.               
                                                                                   Gas Rate 
Model Number           Control               Max BTU/Hr 
Min BTU/Hr          
DHHNT                       THERMOSTAT                 30,000 
15,000
PROPANE/LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" W.C.
Thermostat Pressure 
Regulator Pressure Setting: 10" w.c. 
Gas Inlet Pressure: Max. 13" w.c.
 
Min. 11" w.c. 
SPECIFICATIONS 
AND
 LOCAL CODES 
LOCAL CODES 
Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also 
known as NFPA 54. Available from:
 
American National Standards Institute, Inc. 
National Fire Protection Association, Inc.
 
1430 Broadway 
Batterymarch Park
 
New York, NY 10018 
Quincy, MA 0226
                                                                                   Gas Rate 
Model Number           Control               Max BTU/Hr 
Min BTU/Hr          
DHHPT                       THERMOSTAT                 30,000 
15,000