American Water Heater VG6250T100 Benutzerhandbuch

Seite von 60
14
This water heater shall not be connected to any heating systems or 
component(s) used with a non-potable water heating appliance.
All  piping  components  connected  to  this  unit  for  space  heating 
applications shall be suitable for use with potable water.
Toxic chemicals, such as those used for boiler treatment shall not 
be introduced into this system.
When the system requires water for space heating at temperatures 
higher than required for domestic water purposes, a mixing valve 
must  be  installed.  Please  refer  to  Figure  8  for  suggested  piping 
arrangement.
power supplY
The  water  heaters  covered  in  this  manual  require  a  120  VAC, 
1Ø  (single  phase),  60Hz,  15  amp  power  supply  and  must  also 
be electrically grounded in accordance with local codes or, in the 
absence of local codes, with the National Electrical Code, ANSI/
NFPA 70.
power fluctuatIons and electrIcal noIse
The  water  heater’s  control  system  requires  a  source  of  stable 
clean electricity for proper operation. Connecting the water heater 
to a branch circuit that is subject to fluctuations in voltage level or 
electrical  line  noise  such  as  EMI  (electro  magnetic  interference) 
or  RFI  (radio  frequency  interference)  may  cause  erratic  control 
system operation and malfunction.
A high quality power supply filter/suppressor such as the Kleen Line 
model SELF/T-10 Series SC-L or equivalent must be installed if the 
above conditions exist. Call the technical support phone number 
listed on the back cover of this manual for more information.
 
note:  Malfunctions  caused  by  the  power  supply  and  the  costs 
to  install  power  supply  filters  are  not  covered  under  the  limited 
warranty.
dedIcated power wIrInG and breaKers
Dedicated  power  supply  wires,  ground  wiring  and  dedicated 
circuit breakers often prevent electrical line noise and should be 
considered when installing the water heater.
polarItY sensItIve
The control system on the water heaters covered in this manual is 
polarity sensitive; electronic flame sensing requires correct polarity. 
The control system is programmed to monitor the incoming power 
supply. If the Hot and Neutral wires in the 120 VAC power supply 
are reversed, the control system will declare a Fault condition and 
lock out, heating operation will be disabled until the power supply is 
correctly wired. The control system will display the “AC Reversed” 
Fault message on the LCD.
cheMIcal vapor corrosIon
CORROSION OF THE FLUEWAYS AND vENT SYSTEM MAY 
OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN 
CHEMICAL vAPORS. SUCH CORROSION MAY RESULT IN 
FAILURE AND RISk OF ASPHYXIATION.
Spray  can  propellants,  cleaning  solvents,  refrigerator  and  air 
conditioning  refrigerants,  swimming  pool  chemicals,  calcium 
and sodium chloride (water softener salt), waxes, and process 
chemicals  are  typical  compounds  which  are  potentially 
corrosive.
Do not store products of this sort near the heater. Also, air which is 
brought in contact with the heater should not contain any of these 
chemicals.  If  necessary,  uncontaminated  air  should  be  obtained 
from  remote  or  outside  sources.  The  limited  warranty  is  voided 
when failure of water heater is due to a corrosive atmosphere. (See 
limited warranty for complete terms and conditions).
water pIpInG
HOTTER  WATER  CAN  SCALD: 
Water heaters are intended to produce hot water. Water heated 
to  a  temperature  which  will  satisfy  space  heating,  clothes 
washing, dish washing, cleaning and other sanitizing needs can 
scald  and  permanently  injure  you  upon  contact.  Some  people 
are  more  likely  to  be  permanently  injured  by  hot  water  than 
others.  These  include  the  elderly,  children,  the  physically  or 
developmentally disabled. If anyone using hot water fits into one 
of these groups or if there is a local code or state law requiring 
a certain temperature water at the hot water tap, then you must 
take special precautions. In addition to using the lowest possible 
temperature setting that satisfies your hot water needs, a means 
such as a mixing valve should be used at the hot water taps used 
by these people or at the water heater, see Figure 8. Valves for 
reducing point of use temperature by mixing cold and hot water 
are also available:
Consult  a  Qualified  Installer  or  Service  Agency.  Follow  
manufacturer’s  instructions  for  installation  of  the  valves. 
Before  changing  the  factory  setting  on  the  thermostat,  read  the 
“Temperature Regulation” section in this manual.
InstallInG the new water heater