American Water Heater (A)BCG3 85T500-8N Benutzerhandbuch

Seite von 52
27
draining and flushing
Burn harzard.
Hot water discharge.
Keep  hands   clear  of  drain
valve  discharge.
It is recommended that the water heater storage tank be drained 
and  flushed  every  6  months  to  reduce  sediment  buildup.  The 
water heater should be drained if being shut down during freezing 
temperatures.
to drain the water heater storage tank:
1.  Turn off the electrical supply to the water heater.
2.  Turn  off  the  gas  supply  at  the  Main  Gas  Shutoff  Valve  if 
the water heater is going to be shut down for an extended 
period.
3.  ensure the cold water inlet valve is open.
4.  Open a nearby hot water faucet and let the water run until 
the water is no longer hot.
5.  Close the cold water inlet valve to the water heater.
6.  Connect a hose to the water heater drain valve and terminate 
it to an adequate drain.
7.  Open the water heater drain valve and allow all the water to 
drain from the storage tank.
8.  Close  the  water  heater  drain  valve  when  all  water  in  the 
storage tank has drained.
9.  Close the hot water faucet opened in Step 4.
10.  If the water heater is going to be shut down for an extended 
period, the drain valve should be left open.
to flush the water heater storage tank:
1.  Turn off the electrical supply to the water heater.
2.  ensure the cold water inlet valve is open.
3.  Open a nearby hot water faucet and let the water run until 
the water is no longer hot. Then close the hot water faucet.
4.  Connect  a  hose  to  the  drain  valve  and  terminate  it  to  an 
adequate drain.
5.  ensure  the  drain  hose  is  secured  before  and  during  the 
entire flushing procedure. Flushing is performed with system 
water pressure applied to the water heater.
6.  Open the water heater drain valve to flush the storage tank.
7.  Flush the water heater storage tank to remove sediment and 
allow the water to flow until it runs clean.
8.  Close  the  water  heater  drain  valve  when  flushing  is 
completed.
9.  remove the drain hose.
10.  Fill the water heater - see Filling The Water heater in this 
manual.
11.  Turn on the electrical supply to place the water heater back 
in operation.
12.  Allow the water heater to complete several heating cycles to 
ensure it is operating properly.
expansion on page 13. The Temperature-Pressure relief Valve is 
not intended for the constant relief of thermal expansion.
Temperature-Pressure relief Valve leakage due to pressure build 
up in a closed system that does not have a thermal expansion 
tank installed is not covered under the limited warranty. Thermal 
expansion tanks must be installed on all closed water systems.
DO NOT PLUG The TeMPerATUre-PreSSUre reLIeF 
VALVe OPeNING. ThIS CAN CAUSe PrOPerTy DAMAGe, 
SerIOUS INJUry Or DeATh.
hot water odor
On occasion, hot water may develop a strong odor. If this occurs 
drain the heater completely, flush thoroughly, and refill. If the problem 
persists, chlorination of the heater and replacement of magnesium 
anodes with aluminum anodes may correct the condition.
Occasionally water softener companies recommend removal of 
heater anodes for odor reasons.
Unauthorized removal of the anode(s) will void the warranty.  For 
further information contact your dealer.
anode rod inspection
Property Damage Hazard
Avoid water heater damage.
Inspection and replacement of anode rod required.
CAUTION
The heater tank is equipped with anode rods to provide corrosion 
control. At least once a year the anode rods should be checked 
to determine if replacement is necessary. Initially the anode rods 
are approximately 7/8” in diameter with a 1/8” diameter steel core 
wire running down the center of the anode material. The ANODeS 
ShOULD Be rePLACeD when the 1/8” diameter core wire is 
visible as this means that the anode material has been expended 
in the control of corrosion.
For models with top inlet and outlet, it is recommended that, before 
removing the inner cover for cleaning, inspection or removal of 
inner parts, you obtain two new nipple collars, part no. 9005783205. 
The nipple collars on the heater will usually be damaged when 
removed. New nipple collars will insure that the seal is such as to 
prevent leakage of flue products when properly installed.
note:  Anode rod inspection may need to be made more frequently 
in areas subject to acid rain that obtains their water supply from 
surface water as the low ph will accelerate anode activity.
caution: Close cold water inlet valve serving heater and open 
nearby hot water faucet to relieve the pressure in the heater before 
attempting to remove anode(s) for inspection.