American Water Heater (A)BCG3 85T500-8N Benutzerhandbuch

Seite von 52
29
Prepare the Up-N-Down Transfer kit
The next step is the preparation of the Up-N-Down Transfer kit, 
if you have not already done so:
1.  With the 5 gallon Up-N-Down container in the vertical position, 
unscrew  the  plastic  vent  cap  in  the  handle  and  pierce  the 
plastic membrane over the vent boss under the cap to allow 
the container to vent.
note: If your container does not have the vent cap and vent 
boss, drill a 3/16” hole in the handle.  When you have finished 
deliming  you  will  be  able  to  plug  this  drilled  vent  with  the 
stainless steel screw that is supplied with the kit.
2.  remove  the  container’s  cap  and  cut  the  plastic  membrane 
located in the 3/4” IPT opening in the cap.  Take care to not 
damage the threads.
3.  Find the 3/4” male adapter, apply teflon tape to the threaded 
end and screw it into the 3/4” IPT opening in the cap.
4.  Put cap with male adapter back on the container and slide  
3/4” hose over end of male adapter and fasten in place using 
hose clamp provided.
Delime using Flo-Jug Method
5.  Slide the hose clamp over end of hose and slide hose over the 
male adapter in the water heater drain opening and secure in 
place using hose clamp.
6.  Lift  container  to  the  “Pour”  Position,  see  Figure  28,  being 
careful to keep the vent in the handle above the liquid level 
and pour the UN•LIMe into the heater.
7.  Lower container, you may have to place the container on its 
empty carton to prevent the UN•LIMe from flowing back into 
the container.
8.  Let  UN•LIMe  remain  in  the  heater  for  5  minutes  and  then 
lower the container to the “Drain” Position, see Figure 28.
9.  Deliming activity is indicated by foaming on the surface of the 
UN•LIMe. If there is deliming activity, repeat steps 6 thru 8.
Normally,  lime  removal  will  be  completed  within  one  hour.  
Severe build-up of lime may take longer than an hour to complete 
descaling.
Note: To check UN•LIMe for continued use, place some scale 
or white chalk in a glass with a small amount of UN•LIMe.  If 
the material is vigorously dissolved by the UN•LIMe, it can be 
reused; if not, the UN•LIMe should be replaced.
figure 28.
Chemical Hazard
• Product contains phosphoric acid.
• Keep out of reach of children.
• Use rubber or neoprene gloves.
UN•LIMe contains phosphoric acid. In case of external contact, 
flush with cool water. If irritation persists, get medical attention. If 
swallowed, give 1 or 2 glasses of water or milk and call physician.
Get immediate medical attention for contact with eyes. keep out 
of reach of children.
note: the use of ruBBer or neoprene gloVes is 
recommended, especially if you haVe any open 
sores or cuts to aVoid unnecessary irritation 
or discomfort.
1.  Turn off fuel and/or power supply to heater. Also, turn off power 
to any electrical device or equipment, which is attached, or 
part of the system.
2.  Open  hot  water  side  of  faucet  closest  to  heater  and  allow 
water to run until it is cool enough to handle safely.
3.  Close cold water inlet valve to heater.
4.  Connect  hose  to  drain  valve  at  bottom  of  heater  and  start 
draining heater into suitable floor drain area.
5.  remove relief valve while heater is draining. NOTe: Do not 
replace relief valve until deliming is completed. relief valve 
opening  will  also  act  as  a  vent  in  case  of  possible  contact 
between  the  delimer  and  the  anode  rod(s),  which  may 
produce flammable hydrogen-air mixtures.
6.  If relief valve appears to be limed-up, place it in a clean glass or 
plastic container adequate in size so that you can pour enough 
UN•LIMe®  into  the  container  to  cover  the  valve  and  allow 
space for foaming. When foaming stops, run fresh cool water 
into the container and rinse the relief valve for a few minutes.
7.  If heater does not drain completely after a reasonable length 
of time, turn off the main water supply valve to stop water from 
entering the tank due to a by-pass problem or defective cold 
water inlet valve. Also, check for clogged drain valve opening. 
heater must be completely drained before introducing UN•LIMe.
8.  remove the cleanout cover and place a clean plastic bucket 
next to the cleanout opening.
Partially  open  the  cold  water  inlet  valve  to  allow  time  to 
accomplish the following and then close the valve.
While  the  water  is  being  run  through  the  tank,  insert  a  stiff 
wire, copper tube flattened at one end or an opened wire coat 
hanger  through  the  cleanout  opening  and  scrape  out  any 
loose  deposits  of  scale  or  sediment. This  is  an  economical 
way to avoid unnecessary usage of the deliming solution.
repeat the opening and closing of the cold water inlet valve 
as  necessary  but  be  sure  the  heater  is  completely  drained 
when ready to introduce the UN•LIMe.
Upon completion, reinstall the cleanout cover and use a new 
cleanout cover gasket (part number 9004099215).
remove the drain valve.
9.  Install the long plastic male adapter insert fitting into the drain 
valve opening of heater after applying Teflon tape or paste to 
threads. Tighten firmly by hand and use wrench or adjustable 
pliers to check for secure connection. Do not over tighten to 
avoid damage to threads and fittings.