Remote Control
 
4.1 
Introduction 
The RX8000 Series Receivers can be remotely controlled / monitored in a variety of 
ways: 
•  RS232/485 Remote Control Protocol (RCP) 
•  Director Over-Air Control (Not RX8320) 
• Web 
Browser 
• SNMP 
4.1.1 
Local Control Lockout 
Common for all control methods is that the equipment can still be controlled locally 
from the front panel interface unless the front panel is disabled. This can be 
achieved either: 
•  locally using the front panel menu 1.5.1 FRONT PANEL LOCKOUT to prevent 
local control from being re-established 
•  or remotely using the appropriate remote command, depending on the remote 
control method being used. 
When front panel lockout is set to ON, the user can still browse and navigate the 
front panel menus. However, none of the menu items can be edited (except for 
Menu 1.5.1 to enable/disable front panel lockout). The LCD will continue to display 
summary information screens. 
4.2 
RS232/485 RCP 
RS232/485 Remote Control Protocol (RCP) is only available as an option card on all 
of the RX8000 Series Receivers. 
This enables control of the unit through the RS232/485 serial connector on the rear 
panel of the unit, using Ericsson’s proprietary remote control protocol. This feature 
allows customers, who may be upgrading their current systems to the RX8000 
series, to use their current scripts for receiver control. 
For more detailed information about RS232/485 RCP remote control protocols, 
contact Ericsson. 