Equipment-groups (Annex I of the EC-Directive 94/9/EC)
Group I
(mines, mine gas & dust)
Group II
(other explosive atmospheres gas/dust)
Category M
Category 1
Category 2
Category 3
1
2
G
(gas)
(Zone 0)
D
(dust)
(Zone 20)
G
(gas)
(Zone 1)
D
(dust)
(Zone 21)
G
(gas)
(Zone 2)
D
(dust)
(Zone 22)
for equipment 
providing a 
very high level 
of protection 
when  
endangered by 
an explosive 
atmosphere
for equipment 
providing a 
high level of 
protection when 
likely to  
be endangered 
by an explosive 
atmosphere
for equipment providing  
a very high level of 
protection when used 
in areas where an 
explosive atmosphere 
is very likely to occur
for equipment providing  
a high level of  
protection when used 
in areas where an 
explosive  atmosphere 
is likely to occur
for equipment providing 
a normal level of  
protection when used 
in areas where an 
explosive atmosphere 
is less likely to occur
fIGURE 4
EG. 123456/a/04
SECTION TSM 288
ISSUE
A
PAGE 4 OF  36
seals/area behind the rotor retainers including the threads in 
the shafts should be inspected for seal deterioration or product 
contamination. If any is found then the pump head should be 
fully disassembled, cleaned and sanitized using a combination 
of appropriate cleaning solutions and brushes and new seals 
installed. Refer to Section 5 for seal assembly instructions.
It is recommended that the exterior of the pump be cleaned 
periodically  with  a  non-aggressive,  non-abrasive  cleaning 
solution.
2.5  PUMP MOdEl dEsIGNaTION
The designations of pump models are as follows:
SLAS  SLBS  SLCS  SLDS  SLES  SLFS  SLGS
SLAL  SLBL  SLCL  SLDL  SLEL  SLFL 
SLGL
This information, together with the pump serial number, should 
be  provided  when  requesting  additional  information  on  the 
pump or when ordering spare parts. The pump serial number 
is stamped on the pump nameplate and the casing, (refer to 
section 2.7, Figures 3 and 4).
For  the  maximum  operating  pressures,  temperatures  and 
speeds refer to section 3.3, Figure 7.
2.6  aTEX INfORMaTION PlaTE
2.6.1 EQUIPMENT GROUPs &  
CaTEGORIEs
2.7  PUMP MOdEl aNd sERIal 
NUMbER
Should you require any information regarding your SL Series 
rotary  lobe  pump  contact  Viking  Pump  or  your  Viking  Pump 
(distributor,  providing  the  pump  model  and  serial  number  as 
stated on the pump nameplate, see Figure 3, which is fixed to 
the bearing housing (see Figure 5 for standard pump build).
Should this be damaged or missing, the pump serial number  
is  also  stamped  on  opposite  corners  of  the  casing,  (see  
Figure 4).
figure 3
Nameplate
VIKING PUMP, INC.
A Unit of IDEX Corporation
CEDAR FALLS, IOWA  USA
Phone: (319) 266-1741
Fax: (319) 273-8157