Viking SLGL Benutzerhandbuch

Seite von 36
fIGURE 5
fIGURE 6
6a
6b
6c
6d
6e
flOW
SECTION TSM 288
ISSUE
A
PAGE 5 OF  36
3.3  sl sERIEs PUMP OPERaTING 
PaRaMETERs
The maximum pressure and speed operating parameters are 
given in Figure 7, page 6. In practice these may be limited due 
to the nature of the product to be pumped and/or design of the 
system  in  which  the  pump  is  to  be  installed.  Consult  Viking 
Pump or your distributor for assistance.
If the system or product characteristics are to be changed 
from  the  original  application  for  which  the  pump  was 
selected, Viking Pump or their authorized distributor should 
be consulted to ensure the pump is suitable for the new 
application.
The pump should not be subjected to sudden temperature 
changes  to  avoid  the  risk  of  damage  from  sudden 
expansion/contraction  of  components.  Care  should  be 
taken when selecting pumps for handling liquids containing 
abrasive particles as these may cause wear of pump head 
components. For advice or assistance contact your Viking 
Pump distributor.
2.8  sTaNdaRd PUMP  
COMPONENT TERMs
3.0  GENERal
3.1  sl sERIEs PUMPING  
PRINCIPlE
The  pumping  action  of  the  rotary  lobe  pump  principle  is 
generated  by  the  contra-rotation  of  two  pumping  elements 
(rotors) within a chamber (casing) see Figure 6.
The rotors are located on shafts that in turn are held within a 
bearing housing mounted to the back of the casing. The shaft 
assemblies  comprise  of,  the  shaft  support  bearings  and  the 
timing  gears.    The  gears  transfer  the  energy  from  the  drive 
shaft  to  the  driven  shaft,  synchronizing  the  rotors  such  that 
they rotate without contact with each other.
As  the  rotors  pass  the  suction  port,  Figure  6a,  the  cavity 
increases  creating  a  pressure  decrease,  which  induces  the 
pumped medium to flow into the casing.
The  pumped  medium  is  carried  around  the  casing  by  the 
rotors, Figure 6b and 6c, to the discharge side of the pump, 
Figure 6d. Here the cavity decreases and the pumped medium 
is discharged from the casing, Figure 6e.
For pump component terms see Figure 5.
3.2  ROTaRY lObE PUMP 
PRINCIPlE
WaRNING