3.5  sTaRT UP PROCEdURE
•  Check that all piping and associated equipment 
are clean and free from debris and that all pipe 
connections are secure and leak free.
•  For pumps installed with flushed product seals 
check  that  all  auxiliary  services  are  in  place 
and connected and provide sufficient flow and 
pressure for flushing purposes 
•  Ensure  lubrication  is  provided  for  both  pump 
and drive. SL Series pumps are shipped pre-
filled with grease, refer to section 6.4 grease 
capacities and grades.
•  If an external relief valve is incorporated in the 
system check that it is set correctly. For start 
up  purposes  it  is  considered  good  practice 
to  set  the  relief  valve  lower  than  the  system 
design pressure. On completion of start up the 
relief  valve  should  be  set  for  the  application. 
The required setting should never exceed the 
lower of either the pumps maximum pressure 
rating  or  the  system  design  pressure.  For 
setting integral relief valves, refer to sections 
3.8.1 and 3.8.2.
•  Ensure  both  suction  and  discharge  valves 
are  fully  open,  and  pipe  work  is  free  from 
all  obstructions.  SL  Series  pumps  are  of 
the  positive  displacement  type  and  should 
therefore never be operated against a closed 
valve as this would result in pressure overload, 
resulting in damage to the pump and possibly 
the system.
•  Ensure rotation of the drive shaft is correct for 
the direction of flow required see Figure 9.
•  Ensure product is available in the tank before 
starting pump. This is very important for pumps 
installed  with  un-flushed  product  seals,  as 
these  sealing  arrangements  must  never  be 
allowed to run dry.
•  Before  beginning  operation  it  is  considered 
good  practice  to  momentarily  start/stop  the 
pump  to  check  the  direction  of  rotation  and 
ensure  that  the  pump  is  free  of  obstructions. 
Once  this  has  been  carried  out,  begin 
operation  keeping  a  visual  check  on  suction 
and  discharge  pressure  gauges  and  monitor 
pump temperature and power absorbed where 
possible.
Where  motor  mounted  options  are  to  be  installed  follow  the 
manufactures  recommended  guidelines.  However,  when 
installing a pump complete with base and drive, the following 
guidelines must be observed:
•  The preferred drive arrangement for any rotary 
lobe pump is in-line direct coupled.
•  Flexible couplings must always be incorporated 
and  correctly  aligned  within  the  limits 
recommended  by  the  coupling  manufacturer. 
To  check  coupling  alignment  rotate  the  shaft 
by at least one full revolution and ensure that 
the shaft rotates smoothly.
Couplings of a non-flexible design must never 
be used.
•  Couplings must always be enclosed in a suitable 
guard to prevent contact with rotating parts that 
could result in personal injury. Guards should 
be of suitable material, and of sufficiently rigid 
design  to  prevent  contact  with  rotating  parts 
under normal operating conditions. 
•  When  installing  pump  sets  in  flammable 
or  explosive  environments,  or  for  handling 
flammable  or  explosive  materials,  special 
consideration  must  be  given  not  only  to  the 
safety  aspects  of  the  drive  unit  enclosure 
but  also  to  the  materials  used  for  both  the 
coupling and the guard to eliminate the risk of 
explosion.
•  Baseplates  must  be  secured  to  a  flat  level 
surface such that distortion and misalignment 
are avoided. 
Once baseplates are fastened 
in position the drive alignment must be re-
checked.
•  When  using  electric  motor  drives,  ensure 
that  the  electrical  supply  is  compatible  with 
the drive and controls and that the method of 
wiring is correct for the type of starting required 
by the motor i.e. Direct On Line, or other similar 
method. Ensure all components are correctly 
grounded.
3.4.1 INsTallaTION WITH IN-lINE 
ClEaNING sYsTEMs
The  SL  Series  range  has  been  designed  to  be  effectively 
cleaned  by  procedures  recommended  for  in-line  cleaning  of 
process  plant.  To  assist  in  maximizing  the  effectiveness  of 
cleaning within the pump head it is recommended that during 
the  cleaning  cycle  a  flow  rate  equivalent  to  a  velocity  of  1.5 
metres  per  second  (3.3  feet  per  second);  in  a  pipe  of  equal 
diameter  to  the  rotor  case  connections  is  achieved.  With  a 
differential pressure of 2 to 3 bar (30 to 45 psi) being developed 
across the pump head
For applications where maximum drainage of the pump head is 
required, and / or where in-line cleaning is employed, the pump 
ideally should be mounted with the rotor case connections in 
the  vertical  orientation.  A  procedure  must  be  determined  to 
ensure that the pump is effectively cleaned. It is recommended 
that this cycle would typically include a combination of some 
or  all  of  the  following:  Acidic  or  Caustic  based  Detergents, 
‘Sanitizers’,  Disinfectants  and  Water  rinses.  These  must 
be  appropriate  to  both  the  products  being  handled  and  the 
materials of construction of the pump.