Wi-Ex YX699 Merkblatt

Seite von 2
© 2008 Wi-Ex 
 
 
3.  Turn on the meter with the power switch on the side of the 
signal meter.  After a few seconds, the meter will indicate the 
received signal strength on the display. 
4.  Select the desired band by pressing the BAND button on the 
front of the meter.  The LED will light green for the CEL band 
(800 MHz) or orange for the PCS (1900 MHz) band.  Pressing 
the BAND button again will toggle the meter between the CEL 
and PCS bands. 
5.  The meter will now indicate the received signal strength of the 
selected band.  A greater number indicates a stronger signal. 
6.  The directional antenna may be peaked for the strongest signal 
by turning the antenna and observing the display on the meter.  
Turn the antenna until the strongest signal (greatest number) is 
found. 
7.  Disconnect the cable and antenna, and turn off the meter when 
not in use to maximize battery life. 
 
 
 
   
   NOTE:   To switch between the default numeric display (0 to 99) and the 
alternate dBm display (-99 to -10 dBm), press and hold the BAND 
button for 10 seconds, then release. 
   
 
 
 
   zBoost Professional Signal Meter - Product Specifications: 
Frequency (downlink): 1930 – 1990MHz (1900 MHz) 869 – 894 MHz (800 MHz) 
Signal Indicator Display LED: numeric display 0-99 (default) or dBm display -99dBM 
to -10dBm 
Connectors: RF SMA (female) – PCS and CEL RF input 
Battery (not included): 3 standard AA (1.5VDC) batteries (8-10 hours) 
Base Unit Size:  2” x 4” x 1” 
Operating Conditions: 0° to 50°C (32° to 122°F) 
Storage Conditions: -30° to 125°C (-22° to 257°F)