Mitsubishi Electronics MR-J3 Benutzerhandbuch
5 - 11
5. OPERATION
(b) Selection of point table
Using the input signal or CC-Link, select the point table No. with the remote input and remote register
from the command device (controller) such as a personal computer.
The following table lists the point table No. selected in response to the remote input. When 2 stations
are occupied, the point table No. can be selected by remote register setting. (Refer to section 3.6.3.)
from the command device (controller) such as a personal computer.
The following table lists the point table No. selected in response to the remote input. When 2 stations
are occupied, the point table No. can be selected by remote register setting. (Refer to section 3.6.3.)
Remote input (0: OFF 1: ON)
2 stations occupied
1 station occupied
RY(n 2)5 RY(n 2)4 RY(n 2)3
RYnE RYnD RYnC RYnB RYnA
Selected point
table No.
0 0 0 0 0 0 0 1
1
0 0 0 0 0 0 1 0
2
0 0 0 0 0 0 1 1
3
0 0 0 0 0 1 0 0
4
1 1 1 1 1 1 1 0
254
1 1 1 1 1 1 1 1
255