3 - 17
3. SIGNALS AND WIRING
3.4.3 Terminals
Refer to Section 10.2.1 for the layouts and signal configurations of the terminal blocks.
Connector
Pin No.
Code
Connection target
(Application)
Description
1
L
1
2
L
2
CNP3
3
L
3
Main circuit power
(1) When using a three-phase power supply
Supply L
Supply L
1
, L
2
and L
3
with three-phase, 200 to 230VAC, 50/60Hz
power.
(2) When using a signal-phase power supply
Supply L
(2) When using a signal-phase power supply
Supply L
1
and L
2
with signal-phase, 200 to 230VAC, 50/60Hz
power.
1
L
11
2
L
21
CNP1B
3
Control circuit power
Supply L
11
and L
21
with single-phase, 200 to 230VAC, 50/60Hz
power.
1
N
2
P
CNP1A
3
C
Regenerative brake
option
option
Connect the regenerative brake option across P-C.
Keep N open. (Refer to Section 12.1.1)
Keep N open. (Refer to Section 12.1.1)
Protective earth (PE)
Connect this terminal to the protective earth (PE) terminals of the
servo motor and control box for grounding.
servo motor and control box for grounding.