Mitsubishi Electronics MR-J2M-P8B ユーザーズマニュアル

ページ / 195
3 -  17
3. SIGNALS AND WIRING
3.4.3 Terminals
Refer to Section 10.2.1 for the layouts and signal configurations of the terminal blocks.
Connector
Pin No.
Code
Connection target
(Application)
Description
1
L
1
2
L
2
CNP3
3
L
3
Main circuit power
(1) When using a three-phase power supply
Supply L
1
, L
2
 and L
3
 with three-phase, 200 to 230VAC, 50/60Hz
power.
(2) When using a signal-phase power supply
Supply L
1
 and L
2
 with signal-phase, 200 to 230VAC, 50/60Hz
power.
1
L
11
2
L
21
CNP1B
3
Control circuit power
Supply L
11
 and L
21
 
with single-phase, 200 to 230VAC, 50/60Hz
power.
1
N
2
P
CNP1A
3
C
Regenerative brake
option
Connect the regenerative brake option across P-C.
Keep N open. (Refer to Section 12.1.1)
Protective earth (PE)
Connect this terminal to the protective earth (PE) terminals of the
servo motor and control box for grounding.