Camera OSD settings 
 
This function sets up the text position and colour of the camera name, alarm text or 
DATE/TIME on the screen. Of course, the corresponding ENABLE flag for each 
item shall be ”ON” to activate this function, such as camera name Enable in 
Network setup, Text enable in Alarm setting and Display in DATE/TIME setting. 
When the OSD is off, the message "OSD" will be overlaid in red. Masking is only 
possible when the OSD is off. Make sure not to select the same position for alarm 
text and date/time display. 
 
7.4 
Alarm 
 
External alarms and motion sensors can be set. Connecting a sensor or other 
device to the alarm input terminal signals an alarm when the sensor detects 
trouble.  For example, mounting a sensor on a door notifies an alarm each time the 
door is opened. By setting the motion sensor to activate, an alarm is notified by 
detecting a change in a screen. 
 
Two alarm digital input terminals AL1, AL2 are located on the rear panel. Before 
using the alarm function certain parameters need to be defined.