7.4.1 
External digital input 1 
 
z
 
Set an "Alarm Input" 
ON: Detects an external alarm. 
OFF: Does not perform alarm detection.  
Î
 
The following functions will be enabled if “ Alarm Input” is set to “ON” 
z
 
Set "Input type" for alarms 
Normally Open (NO): A dry-contact detecting way, opened if nothing occurs but 
closed in case of an alarm. 
Normally Closed (NC): A dry-contact detecting way, closed if nothing occurs but 
open in case of an alarm. 
z
 
Set "TEXT Enable" for alarms 
A noticeable message of alarm can be displayed on screen if this item is set to 
“ON”. 
z
 
Enter "Text" for alarm message 
Max 24 characters can be entered. 
z
 
Set "Audio out" for alarm message 
An audio alarm message can be sent to an external speaker if this item set to 
“ON”. 
 
 
 
 
 
NOTE 
A speaker with integrated amplifier can be connected to the AUDIO out jack on the rear panel. 
 
 
 
z
 
Select "EVENT” 
Pre-recorded voice files with extension .wav that have been uploaded to SD 
memory card in advance can be selected as voice alarm message. Up to 4 kinds 
of audio source can be selected. 
7.4.2 
External digital input 2 
 
All configurations are the same as for Alarm digital 1, except that an additional 
input mode – enforced BW – is added, which will switch the camera to 
monochrome mode if a trigger signal is received.