Siemens TC12 Benutzerhandbuch
TC12 Installation, Commissioning & Maintenance Handbook
Table 6 - Outstation Processor PCB - PL1
50-way connector to LMU inputs.
PIN
NAME
PIN
NAME
1
LMU Input 1+
27
LMU Input 14+
2
LMU Input 1-
28
LMU Input 14-
3
LMU Input 2+
29
LMU Input 15+
4
LMU Input 2-
30
LMU Input 15-
5
LMU Input 3+
31
LMU Input 16+
6
LMU Input 3-
32
LMU Input 16-
7
LMU Input 4+
33
LMU Input 17+
8
LMU Input 4-
34
LMU Input 17-
9
LMU Input 5+
35
LMU Input 18+
10
LMU Input 5-
36
LMU Input 18-
11
LMU Input 6+
37
LMU Input 19+
12
LMU Input 6-
38
LMU Input 19-
13
LMU Input 7+
39
LMU Input 20+
14
LMU Input 7-
40
LMU Input 20-
15
LMU Input 8+
LMU Input 21+
41
16
LMU Input 8-
42
LMU Input 21-
17
LMU Input 9+
43
LMU Input 22+
18
put 22-
LMU Input 9-
44
LMU In
19
LMU Input 10+
45
LMU Input 23+
20
LMU Input 10-
46
LMU Input 23-
21
LMU Input 11+
47
LMU Input 24+
22
LMU Input 11-
48
LMU Input 24-
23
LMU Input 12+
49
ZX0 Input +
24
LMU Input 12-
50
ZX0 Input -
25
LMU Input 13+
26
LMU Input 13-
666/HE/43100/000
Page 79