Senco PC2016 Benutzerhandbuch

Seite von 16
12 
 
 
 
 
      
 
                 Senco
®
 Electric Air Compressor Manual 2004
TROUBLESHOOTING
 1. 
Motor will not run or restart.
REMEDY 
Plug cord into grounded outlet. 
 
Move switch to "AUTO" position. 
 
Turn air compressor off, wait until motor is cool, then 
press motor thermal overload (red) button firmly until 
click is heard.   
 
Replace fuse or reset circuit breaker.
Check for proper fuse;  only "Fusetron" type T fuses 
are acceptable.
Check for low voltage conditions.
Disconnect any other electrical appliances from 
circuit  or operate air compressor on its own branch 
circuit.
Check chart on page #10 for proper gauge wire and 
cord length.
When pilot valve is set in the Start/Stop position, 
motor will start automatically when air tank pressure 
drops below "cut-in" pressure of motor/pressure 
switch.
Bleed the line by moving the switch to the "Off" posi-
tion.
Remove and clean or replace.
Contact Senco Customer Service @ 800-543-4596
PROBABLE CAUSE 
Power cord not plugged in. 
 
Motor/Pressure switch in "OFF" position. 
 
Motor thermal overload switch has tripped.
Fuse blown or circuit breaker has tripped. 
 
 
Wrong gauge wire or length of extension cord. 
 
Air tank pressure exceeds motor/pressure switch 
"cut-in" pressure.
 
Pressure release valve on motor/pressure switch has 
not unloaded pump head pressure.
Pilot valve's check valve stuck open.
Defective motor, motor capacitor or motor/pressure 
switch.
SYMPTOM
 2. 
Noisy operation.
REMEDY 
Tighten pulley and or flywheel. 
 
Add correct amount of oil. Check for bearing dam-
age. 
 
Remove cylinder head and inspect.  Clean or re-
place. 
 
STOP THE COMPRESSOR!  Contact Senco  
Customer Service @ 800-543-4596.
PROBABLE CAUSE 
Loose motor pulley or pump flywheel. 
 
Lack of oil in the pump.   
 
Carbon deposits on pistons or valves. 
 
Bearing, piston or connecting rod failure. 
SYMPTOM