Senco PC2016 Benutzerhandbuch

Seite von 16
14 
 
 
 
 
      
 
                 Senco
®
 Electric Air Compressor Manual 2004
TROUBLESHOOTING
REMEDY 
Adjust pressure regulator knob to proper setting or 
replace. 
 
Clean or replace. 
 
Check for leaks and repair. 
 
Replace with larger hose or connectors. 
 
Tighten or replace. 
 
Check the accessory air requirement. If it is higher 
than the CFM or pressure supply of the air  
compressor, you need a larger air compressor.
PROBABLE CAUSE 
Pressure regulator knob not turned to high enough  
pressure or defective pressure regulator.
Restricted air intake filter.
Air leaks. 
Hose or hose connections are too small or long. 
 
Slipping belt. 
 
Air compressor is not large enough for air require-
ment.
SYMPTOM
 11. 
Insufficient pressure at air tool or accessory.
REMEDY 
Change oil and move air compressor to a less humid 
environment. 
PROBABLE CAUSE 
Water in oil due to condensation.
SYMPTOM
 14. 
Oil has milky appearance.
REMEDY 
Clean or replace. 
 
Drain air tank and measure pump up time.  Compare 
to specifications.  If longer, remove pump head and 
inspect valve plate, clean or replace. 
 
Clean or replace. 
PROBABLE CAUSE 
Restricted air intake filter. 
Defective (reed) valve. 
 
 
Restriction in pilot valve.
SYMPTOM
 12. 
Air compressor not making enough air.
REMEDY 
Clean or replace. 
 
Do not incline the air compressor more than 10° in 
any direction while running. 
 
Drain oil.  Refill to proper level with Senco PC0344 
oil. 
 
Clean. 
 
Repair. 
 
Contact Senco Customer Service 800-543-4596.
PROBABLE CAUSE 
Restricted air intake filter.
Air compressor on unlevel surface. 
 
Crankcase overfilled with oil. 
 
Plugged oil dipstick vent. 
 
Oil leaks. 
 
Worn piston rings or scored cylinder.
SYMPTOM
 13. 
Excessive oil consumption in pump. 
REMEDY 
Drain air tank after every use.  Drain air tank more 
often in humid weather and use an air line filter.
PROBABLE CAUSE 
Condensation in air tank caused by high level of at-
mospheric humidity or air compressor is not run long 
enough.
SYMPTOM
 15.  Moisture in discharge air.