OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
No weld output in AC or DC Modes.
The  auxiliary  power  (480,  23  &
115VAC)  is    normal.    Engine  runs
normally.
1.  Check  the  welding  cables,
clamps  and  electrode  holder  for
loose or broken connections.
2.  Check  the  open  circuit  voltage
(OCV) at the welder output termi-
nals,  engine  at  high  idle  (3650
RPM).  Normal maximum is 73 to
80VAC.  Normal DC maximum is
67 to 72VDC.  If the OCV is OK
then proceed to Step #2.
1.  Disconnect  lead  W1  from  the
Output  Bridge  (D1)  and  check
for the presence of 80VAC from
lead W1 to lead W2 on the main
stator winding.  See the Wiring
Diagram
.  
  If  the  AC voltage  is
NOT present, the winding in the
stator may be faulty.  Check the
winding for continuity and test to
be  sure  it  is  NOT grounded  to
the  stator  iron.    Replace  the
Sstator if necessary.  If the cor-
rect AC voltage is present, pro-
ceed to step #2.
2.  Check  the  Reactor,  Range
Switch  (S1)  and  associated
wires for loose or faulty connec-
tions.    Check  the  reactor  wind-
ing for continuity and test to be
sure  it  is  NOT  grounded  to  the
reactor iron.
3.  Check  the  Choke  (L1),  Polarity
Switch  (S2)  and  associated
wires for loose or faulty connec-
tions.  Check the choke winding
for continuity and test to be sure
it is NOT grounded to the choke
iron.
4.  Check the weld output terminals
and  associated  wires  for  loose
or faulty connections.
5.  Perform  the  Output  Bridge
TROUBLESHOOTING AND REPAIR
F-5
F-5
RANGER® 3 PHASE
No DC welding output.  AC welding
output  and  auxiliary  power  is  nor-
mal.
1.  Make sure the Polarity Switch is
in  the  proper  position  and  is
“seated” correctly.
2.  Make  sure  the  electrode  and
polarity  are  correct  for  the
process being used.
1.  Perform the Output Bridge Test.
2.  Check  the  Choke  (L1),  the
Polarity Switch (S2) and associ-
ated  wires  for  loose  or  faulty
connections.    Check  the  choke
winding for continuity and test to
be sure it is NOT grounded  the
choke iron.