ITB alienation sensor
1.
Open the right door.
2.
Lower the secondary transfer assembly.
3.
Remove the ITB.
4.
Rotate the gear (callout 1) to move the flag (callout 2). If the flag does not actuate, replace the ITB.
Figure 3-13
  Test the ITB alienation sensor (1 of 2)
1
2
5.
Remove all print cartridges.
NOTE:
Cover all removed print cartridges with paper.
6.
Locate the sensor behind the cyan OPC drum position.
ENWW
Tools for troubleshooting