11.6 Disassembly and Replacement
[A] Cleaner unit
(1) Open the front cover, take off the toner bag
(1) Open the front cover, take off the toner bag
and front cover ( Chapter 2.5.1 [A]).
(2) Take off the developer unit ( Chapter
12.5 [A]).
(3) Open the bypass unit, ADU and jam access
cover.
(4) Release the latch and remove the toner bag
full detection sensor-2.
(5) Loosen 2 screws and take off the cleaner
unit.
Notes:
1. Hold the cleaner unit which has been taken off
1. Hold the cleaner unit which has been taken off
as shown in the figure.
2. Do not touch the drum surface.
[B] Main charger
(B-1) Main charger
(1) Take off the cleaner unit ( Chapter 11.6
(B-1) Main charger
(1) Take off the cleaner unit ( Chapter 11.6
[A]).
(2) Release the latch and pull out the main
charger to the direction of the arrow.
Note:
Be careful not to touch or scratch the drum
surface at this time.
Be careful not to touch or scratch the drum
surface at this time.
(B-2) Main charger grid
(1) Push the terminal head at the front side and
(1) Push the terminal head at the front side and
remove the grid.
Note:
Do not touch the mesh area of the grid.
Do not touch the mesh area of the grid.
Fig. 11-601