Real-Time Data Timing 
When transmitting data at fast update rates, consideration must be given to the amount 
of time that it takes to transmit a single message.  If the transmission time exceeds the 
update rate, it is impossible for the LS8000-3 to transmit all data.  Ethernet UDP is fast 
enough that this does not occur, but it can occur over RS-232 and RS-422.  For 
example, if the RS-232 baud rate were set to 57.6k, a TE data reading would take 
4.86ms to transmit.  If the User Update Rate is set to 4ms, this will result in every other 
message being skipped, resulting in an actual update rate of 8 ms.  The gauge's 
measurements will not be affected by this—it will still produce accurate measurements. 
 
 
The following table lists the fastest update rate possible for each baud rate.  If using TB 
mode, the framing must be set to an 8n1 mode. 
 
 
Transmission Time 
Fastest Update Rate 
Baud Rate 
1 Byte 
TE 
TB 
TE 
TB 
230.4k 43.4µs 
1.22ms 
694µs  2ms 
1ms 
115.2k 86.8µs 
2.43ms 
1.39ms  3ms 
2ms 
57.6k 173µs 
4.86ms 
2.78ms 5ms  3ms 
38.4k 226µs 
7.29ms 
4.16ms 8ms  5ms 
19.2k 521µs 
14.6ms 
8.33ms 15ms  9ms 
9600 
1.04ms 29.2ms 16.7ms  30ms 
17ms 
4800 
2.08ms 58.3ms 33.3ms  59ms 
34ms 
 
When sending real-time data over Ethernet, you can either use the UDP or TCP 
protocols, but UDP is recommended.  The TCP protocol has so much overhead that 
the maximum update rate will be on the order of 200ms.  The UDP protocol has very 
little overhead, so it is easily able to transmit data every 1ms.