Spectralink 1728 Benutzerhandbuch

Seite von 64
18   
R
EFERENCE
 & I
NSTALLATION
 M
ANUAL
 
  
4.4.3
B
YPASS
 P
ROGRAMMING
Sections [302] to [348]: User Codes 002 to 048
Option [3] OFF = Bypass Programming Disabled 
Option [3] ON
= Bypass Programming Enabled (default)
User codes with this option enabled can perform Bypass Programming in assigned partitions. 
4.4.4
S
TAY
 A
RMING
Sections [302] to [348]: User Codes 002 to 048
Option [4] OFF = Stay Arming Disabled 
Option [4] ON
= Stay Arming Enabled for selected User Code (default)
User codes with this option enabled can Stay Arm assigned partitions.
4.4.5
F
ORCE
 A
RMING
Sections [302] to [348]: User Codes 002 to 048
Option [5] OFF = Force Arming Disabled (default)
Option [5] ON
= Force Arming Enabled for selected User Code
User codes with this option enabled can Force Arm assigned partitions.
4.4.6
A
RM
 O
NLY
Sections [302] to [348]: User Codes 002 to 048
Option [6] OFF = Arm Only Disabled (default)
Option [6] ON
= Arm Only Enabled for selected User Code
The user code with this option enabled can arm assigned partitions, but  cannot disarm any partitions. The
type of arming is dependent on the other User Code Options selected. Please note that with the Arm Only
option, the user can cancel a recently armed system by re-entering the access code before the end of the
Exit Delay.
4.4.7
PGM A
CTIVATION
Sections [302] to [348]: User Codes 002 to 048
Option [7] OFF = User Code follows User Code Options and can activate a PGM (default)
Option [7] ON
= User Code can activate a PGM only 
With option [7] off, entering the access code will arm or disarm according to the programmed User Code
Options 
as well as activate or deactivate a PGM. The appropriate PGM Activation/Deactivation Event must
also be programmed (see page 41). With option [7] on, the control panel will ignore all other User Code
Options
. Therefore, entering the access code will only activate or deactivate the PGM. 
4.5
LOCK MASTER CODE
Section [127]: System Options
Option [4] OFF = Lock System Master Code Disabled (default)
Option [4] ON
= Lock System Master Code Enabled
With this feature enabled, the control panel will lock the System Master Code (001). This means that the System
Master Code 
cannot be deleted, but it can be changed.
4.6
DURESS CODE
Section [127] = System Options
Option [6] OFF = Duress Code Disabled (default)
Option [6] ON
= User Code 048 becomes a Duress code
With this feature enabled, User Code 048 becomes a Duress Code. When forced to arm or disarm their system,
users can enter a Duress Code (User Code 048) to arm or disarm the system which can immediately transmit a
silent alert to the Central Station, transmitting the duress report code programmed in section [196].